{"product_id":"amn33-yokogawa-nest-for-communication-modules","title":"AMN33 | Yokogawa Nest for Communication Modules","description":"\u003ch2\u003eYokogawa AMN33 Nest for Communication Modules\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa AMN33-S2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAMN33\u003c\/strong\u003e Nest for Communication Modules, operates as a dedicated hardware component for managing communication module integration within CENTUM CS 1000, CS 3000, and VP distributed control systems. It provides a robust mechanical and electrical platform for modular signal routing and subsystem interconnection.\u003c\/p\u003e\n\u003ch3\u003eHardwareSpecifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa AMN33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg (unloaded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e127 mm × 152 mm × 254 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 degC (operating), -40 to 85 degC (storage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e3.5-5.0 W (nest only, modules excluded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupportedModules\u003c\/td\u003e\n\u003ctd\u003eACM12, communication subsystem modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputType\u003c\/td\u003e\n\u003ctd\u003eVoltage, Current, RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputVoltageRange\u003c\/td\u003e\n\u003ctd\u003e±10 V to ±100 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputCurrentRange\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTDTypes\u003c\/td\u003e\n\u003ctd\u003ePt100, Ni120, Cu50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSamplingRate\u003c\/td\u003e\n\u003ctd\u003e100 samples\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectricalIsolation\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;100 MΩ at 500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidityLimits\u003c\/td\u003e\n\u003ctd\u003e5-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanicalShock\u003c\/td\u003e\n\u003ctd\u003eUp to 10 G operational shock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e1.5 G continuous, 10-150 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e\u003cstrong\u003eProcessControl-DCSConnectivityFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports 4-20 mA HART loop protocol for analog signal integration.\u003c\/li\u003e\n\u003cli\u003eProvides channel-to-channel isolation to prevent signal interference between communication modules.\u003c\/li\u003e\n\u003cli\u003eCompatible with FOUNDATION Fieldbus and Profibus PA connectivity for subsystem integration.\u003c\/li\u003e\n\u003cli\u003eCold junction compensation (CJc) is supported for RTD measurements to maintain thermal accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFrequentlyAskedQuestions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eQ: Does the AMN33 support hot-swap of communication modules?\u003cbr\u003eA: The unit requires modules to be powered down prior to installation or removal; it does not support hot-swap of internal communication modules.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum internal bus current available for installed modules?\u003cbr\u003eA: The internal backplane supplies up to 5.0 W per nest overhead; modules should be accounted for separately to avoid exceeding the bus capacity.\u003c\/p\u003e\n\u003cp\u003eQ: Is firmware on the communication modules updated via the AMN33?\u003cbr\u003eA: Firmware updates are managed through the host DCS interface; the AMN33 itself does not perform firmware flashing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFieldInstallationGuidelines\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMount the AMN33 on standard DIN or panel fixtures ensuring the chassis is properly grounded.\u003c\/li\u003e\n\u003cli\u003eMaintain at least 50 mm spacing from heat-generating devices to avoid thermal accumulation.\u003c\/li\u003e\n\u003cli\u003eRoute signal cables using shielded conduits; connect shields to ground at a single point to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003eVerify orientation of modules and secure locking mechanisms to avoid vibration-induced disconnection.\u003c\/li\u003e\n\u003cli\u003eAvoid crossing power and signal lines in tight proximity to reduce electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44150359097432,"sku":"AMN33","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/AMN33-3.jpg?v=1779937746","url":"https:\/\/www.industriaxplc.com\/products\/amn33-yokogawa-nest-for-communication-modules","provider":"IndustriaX Limited","version":"1.0","type":"link"}