{"product_id":"allen-bradley-1769-pa2-compactlogix-power-supply-module","title":"Allen-Bradley 1769-PA2 CompactLogix Power Supply Module","description":"\u003ch2\u003eAllen-Bradley 1769-PA2 CompactLogix Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for DC backplane power conversion in CompactLogix controller assemblies, the \u003cstrong\u003eAllen-Bradley 1769-PA2\u003c\/strong\u003e (\u003cstrong\u003e1769-PA2\u003c\/strong\u003e Power Supply Module) provides direct electrical power distribution for CompactLogix 1769 I\/O systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1769-PA2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eCompactLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120\/220 VAC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85-265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.40 kg (0.88 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e100 VA at 120 VAC; 130 VA at 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e8 W at 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Capacity\u003c\/td\u003e\n\u003ctd\u003e2 A at 5 VDC; 0.8 A at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inrush Current\u003c\/td\u003e\n\u003ctd\u003e25 A at 132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003ePanel mount and DIN rail mount supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Screw Torque\u003c\/td\u003e\n\u003ctd\u003e1.16 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Distance Rating\u003c\/td\u003e\n\u003ctd\u003eUp to 8 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e662468992954\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control Platform Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1769-PA2\u003c\/strong\u003e operates within the CompactLogix 1769 platform and supplies regulated power to connected controller and I\/O modules. The module supports distributed I\/O density scaling through the 1769 backplane architecture. Therefore, system designers can calculate available current capacity before installing additional I\/O modules.\u003c\/p\u003e\n\u003cp\u003eThe CompactLogix platform uses backplane communication to exchange data between controller components and local I\/O modules. Additionally, proper module loading calculations help maintain stable power distribution across the assembled rack configuration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input voltage range does the 1769-PA2 support?\u003cbr\u003eA: The 1769-PA2 accepts an input voltage range of 85-265 VAC and supports nominal 120 VAC or 220 VAC operation.\u003c\/p\u003e\n\u003cp\u003eQ: How much current can the 1769-PA2 provide to the CompactLogix system?\u003cbr\u003eA: The module provides a maximum output capacity of 2 A at 5 VDC and 0.8 A at 24 VDC for connected 1769 system components.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 1769-PA2 be installed on a DIN rail?\u003cbr\u003eA: Yes. The 1769-PA2 supports both DIN rail mounting and panel mounting configurations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 1769-PA2 according to the CompactLogix system power calculation requirements. Verify the total module load before connecting additional 1769 series I\/O modules.\u003c\/p\u003e\n\u003cp\u003eUse appropriate industrial wiring practices for AC input connections. Separate power wiring from low-level signal cables to reduce electrical interference. Connect protective grounding according to the enclosure and control panel grounding scheme.\u003c\/p\u003e\n\u003cp\u003eConfirm that the mounting method provides sufficient mechanical support. Tighten mounting hardware according to the specified torque value. Inspect terminal connections before energizing the system.\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":44551584219224,"sku":"1769-PA2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/1769-PA2-3_1200x1200_61e60143-71bb-49c4-91e1-35ba14adf4ae.jpg?v=1786434515","url":"https:\/\/www.industriaxplc.com\/products\/allen-bradley-1769-pa2-compactlogix-power-supply-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}