{"product_id":"ai810-3bse008516r1-abb-analog-input-8-ch","title":"ABB 3BSE008516R1 AI810 Analog Input Module","description":"\u003cp\u003eThe ABB AI810 (3BSE008516R1) is a high-performance, 8-channel analog input module designed for the S800 I\/O distributed control system. This module provides versatile signal processing, allowing each of its eight channels to be independently configured for current (0–20 mA, 4–20 mA) or voltage (0–10 V, 2–10 V) inputs. Engineered for demanding industrial environments, the AI810 includes 12-bit resolution and supports HART communication, ensuring transparent transmission of digital diagnostics alongside analog process values.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8 single-ended, unipolar input channels.\u003c\/li\u003e\n\u003cli\u003eIndependent channel configuration for voltage or current signals.\u003c\/li\u003e\n\u003cli\u003eIntegrated HART communication support for intelligent field device integration.\u003c\/li\u003e\n\u003cli\u003eEnhanced protection with PTC current-limiting resistors on all inputs.\u003c\/li\u003e\n\u003cli\u003eShort-circuit protection against transmitter supply voltages up to 30 V DC.\u003c\/li\u003e\n\u003cli\u003e12-bit analog-to-digital conversion accuracy.\u003c\/li\u003e\n\u003cli\u003eElectrical isolation of the 8-channel group from ground.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRefinery and petrochemical process control for pressure, flow, and level monitoring.\u003c\/li\u003e\n\u003cli\u003eTurbine auxiliary system instrumentation, including lube oil and steam monitoring.\u003c\/li\u003e\n\u003cli\u003eBoiler combustion control and water level management.\u003c\/li\u003e\n\u003cli\u003eRenewable energy site management for hydraulic and pitch control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAI810 (3BSE008516R1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signals\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA, 0-10 V, 2-10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance (Current)\u003c\/td\u003e\n\u003ctd\u003e250 ohm (PTC included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance (Voltage)\u003c\/td\u003e\n\u003ctd\u003e290k ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Input Voltage (Non-destructive)\u003c\/td\u003e\n\u003ctd\u003e30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulebus Current (+5V)\u003c\/td\u003e\n\u003ctd\u003e70 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulebus Current (+24V)\u003c\/td\u003e\n\u003ctd\u003e40 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 V AC (Dielectric test)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system is powered down before inserting or removing the module from the Module Termination Unit (MTU).\u003c\/li\u003e\n\u003cli\u003eThe AI810 is compatible with various MTUs, including TU810, TU812, TU814, TU818, TU830, TU833, TU835, TU838, and TU850.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for field signals to minimize EMI\/RFI interference; ensure the shield is properly grounded at the cabinet entry.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation in the control cabinet to stay within operating temperature limits.\u003c\/li\u003e\n\u003cli\u003eEnsure all field wiring is secured and checked for correct polarity before applying power to the loop.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs the ABB AI810 compatible with older S800 systems?\u003c\/h3\u003e\u003cp\u003eYes, the AI810 is a standard component of the ABB S800 I\/O platform and is designed for seamless integration into existing S800 architectures using compatible MTUs.\u003c\/p\u003e\u003ch3\u003eDoes the module support HART?\u003c\/h3\u003e\u003cp\u003eYes, the AI810 supports HART communication, allowing digital data to pass through the module alongside the analog signal.\u003c\/p\u003e\u003ch3\u003eWhat protection is provided for the input channels?\u003c\/h3\u003e\u003cp\u003eThe module features PTC resistors on each channel to limit current, protecting the circuitry against short circuits to the transmitter supply up to 30 V DC.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44701759864920,"sku":"3BSE008516R1","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_9a1c7141-4455-4868-a562-defa1fb18b3b.jpg?v=1788391955","url":"https:\/\/www.industriaxplc.com\/products\/ai810-3bse008516r1-abb-analog-input-8-ch","provider":"IndustriaX Limited","version":"1.0","type":"link"}