{"product_id":"afv10d-s41451-yokogawa-field-control-unit","title":"AFV10D-S41451 | Yokogawa Field Control Unit","description":"\u003ch2\u003eYokogawa AFV10D-S41451 Field Control Unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa AFV10D-S41451\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAFV10D\u003c\/strong\u003e Field Control Unit, operates as a dedicated hardware component for process control execution and I\/O module communication management within CENTUM VP platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecifications \/ Selections\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAFV10D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eField Control Unit for CENTUM VP (Duplexed Vnet\/IP, 19-inch Rack Mountable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-S\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eStandard Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-Redundant Power Supply\u003c\/td\u003e\n\u003ctd\u003e100 - 120 V AC, 50\/60 Hz Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic Software License\u003c\/td\u003e\n\u003ctd\u003eFor Standard Functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSub-system Communication\u003c\/td\u003e\n\u003ctd\u003eLFS1150 Node Expansion License \/ Communication capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLayer 3 Network\/Options\u003c\/td\u003e\n\u003ctd\u003eHigh-speed, specific regulatory, or environmental specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDesign Code\u003c\/td\u003e\n\u003ctd\u003eRevision\/Style code designated by Yokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Brand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e15 to 18 kg (Depending on specific modules installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 19-inch rack-mountable width, depth configurations vary by enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApproximately 200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e10 to 90 % RH (No condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Change Rate\u003c\/td\u003e\n\u003ctd\u003eWithin \\pm10 degC\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 V AC for 1 minute (between power and grounding terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Network\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP (Dual-redundant 1000 Mbps Ethernet-based control network)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Redundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant (Duplex) CPU modules with automatic bump-less switchover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and Instrumentation Integration\u003c\/h3\u003e\n\u003cp\u003eThe hardware implements dedicated control processing for instrument loops, incorporating native processing pathways for 4-20 mA HART loop protocol parameters and external digital communication fieldbuses. Channel-to-channel isolation architecture prevents ground loop propagation across connected I\/O nodes, protecting internal processor circuitry from field-side electrical surges. For thermal measurement loops connected via peripheral nodes, internal algorithmic cold junction compensation (CJC) processing maintains digitization accuracy across varying cabinet temperatures. Continuous dual-redundant memory synchronization replicates variables between active and standby CPU modules, limiting control transfer disruption during automated switchover events.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the restrictions regarding hot-swapping modules within the duplex configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: CPU modules, power supply units, and I\/O communication cards can be replaced online (hot-swapped) without suspending controller execution. The standby module must achieve complete data synchronization with the active controller prior to removing any redundant hardware components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is the system grounding configured to avoid signal interference across the Vnet\/IP control network?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The grounding terminal requires connection to an isolated, dedicated instrumentation ground loop with a grounding resistance value meeting local electrical codes (typically less than 100 Ohms). Power line ground and signal cable shields must be isolated from the structural frame to mitigate electrical noise injection.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Structure:\u003c\/strong\u003e Install the unit into a standard 19-inch rack or dedicated system cabinet using standard securing fasteners to prevent physical strain or misalignment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Ensure vertical clearance zones above and below the chassis are kept clear of structural obstructions to permit unhindered natural air cooling or cabinet fan-driven convection airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e Route standard AC power lines separately from high-speed Vnet\/IP communication lines and low-voltage field signal cables to minimize electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding Ground Continuity:\u003c\/strong\u003e Terminate all external ESB\/ER bus cable shielding frames firmly to the chassis ground at the entrance panel using heavy-duty grounding clamps.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44187184627800,"sku":"AFV10D-S41451","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/AFV10D-S41451-2.jpg?v=1780629226","url":"https:\/\/www.industriaxplc.com\/products\/afv10d-s41451-yokogawa-field-control-unit","provider":"IndustriaX Limited","version":"1.0","type":"link"}