{"product_id":"afs10d-duplex-field-control-unit-yokogawa","title":"AFS10D | Duplex Field Control Unit | Yokogawa","description":"\u003ch2\u003eYokogawa AFS10D Duplex Field Control Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for deterministic execution of regulatory control loops in CENTUM VP and CENTUM CS 3000 platforms, the \u003cstrong\u003eYokogawa AFS10D\u003c\/strong\u003e (base model \u003cstrong\u003eAFS10D\u003c\/strong\u003e Field Control Unit) provides direct physical and electrical interfacing between Remote I\/O nodes and the Vnet\/IP control network.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAFS10D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDuplexed Field Control Unit (for RIO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix Codes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-S\u003c\/td\u003e\n\u003ctd\u003eStandard type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e100 - 120 V AC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e220 - 240 V AC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e24 V DC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP Type \/ Dual-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e482.6 mm x 310 mm x 265 mm (19-inch rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e410 VA (max, AC); 8 A (24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100-120 VAC, 220-240 VAC, 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant CPU, Power, Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP \/ VL net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFOUNDATION Fieldbus \u0026amp; Profibus PA Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe AFS10D interfaces with field devices via Remote I\/O nodes supporting FOUNDATION Fieldbus H1 and Profibus PA protocols. The control bus maintains deterministic cyclic data exchange with a 50 ms update rate. Channel-to-channel isolation is enforced at 500 VDC to suppress transient noise coupling from field wiring. Cold junction compensation is applied internally for connected thermocouple inputs through the associated I\/O modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum inrush current when hot-swapping a power supply module?\u003c\/p\u003e\n\u003cp\u003eA: The redundant power supply allows hot-swap replacement with an inrush current not exceeding 30 A for 50 ms. Verify voltage compatibility before insertion.\u003c\/p\u003e\n\u003cp\u003eQ: Is battery-backed memory retained during complete power loss?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Main memory contents are preserved via a lithium battery backup, maintaining volatile data during outages. Battery replacement requires a scheduled shutdown.\u003c\/p\u003e\n\u003cp\u003eQ: What is the failover time between the active and standby CPUs?\u003c\/p\u003e\n\u003cp\u003eA: Bumpless transfer occurs within 10 ms. Output states remain unchanged during the transition.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the unit in a standard 19-inch rack with 150 mm rear clearance for bus cabling. Ground the chassis using a 5\/16 inch ring terminal connected to the plant earth grid. Terminate all shield drains at the controller end only. Torque power terminals to 1.2 Nm. Set RIO bus termination switches to ON for the final physical node.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44209002905688,"sku":"AFS10D","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/AFS10D-3.jpg?v=1780972082","url":"https:\/\/www.industriaxplc.com\/products\/afs10d-duplex-field-control-unit-yokogawa","provider":"IndustriaX Limited","version":"1.0","type":"link"}