{"product_id":"adv551-p00-d5a00-yokogawa-digital-output-module-32-channels","title":"ADV551-P00\/D5A00 Yokogawa Digital Output Module-32 Channels","description":"\u003ch2\u003eYokogawa ADV551-P00\/D5A00 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for 24 VDC transistor signal switching in CENTUM and related Yokogawa control platforms, the \u003cstrong\u003eYokogawa ADV551-P00\/D5A00\u003c\/strong\u003e (\u003cstrong\u003eADV551\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution for 32-channel discrete output transmission. The module supports current sink output architecture with isolated channel grouping, external 24 VDC supply operation, and ON\/OFF pulse output handling through dedicated terminal and MIL cable interfaces.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode Segment\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV551\u003c\/td\u003e\n\u003ctd\u003e32-channel digital output module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-P00\u003c\/td\u003e\n\u003ctd\u003eBasic type without additional functional expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/D5A00\u003c\/td\u003e\n\u003ctd\u003eKS cable interface adapter included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV551-P00\/D5A00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent sink transistor output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Applied Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 50 mA\/channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e20.4 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e100 mA\/channel at 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput ON Voltage\u003c\/td\u003e\n\u003ctd\u003e2 VDC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-State Leak Current\u003c\/td\u003e\n\u003ctd\u003e0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kVAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInter-Common Isolation\u003c\/td\u003e\n\u003ctd\u003e500 VAC for 1 minute per 16-channel group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width Range\u003c\/td\u003e\n\u003ctd\u003e8 ms to 7200 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width Resolution\u003c\/td\u003e\n\u003ctd\u003e8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelay Tolerance\u003c\/td\u003e\n\u003ctd\u003eMaximum 1 ms ON\/OFF transition delay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal, AKB331 cable, MIL connector cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e700 mA at 5 VDC, 60 mA external supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.2 cm x 10.6 cm x 13 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg to 0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe ADV551-P00\/D5A00 implements grouped electrical isolation between output signal circuits and internal system circuitry. Isolation withstand capability is specified at 2 kVAC for 1 minute between output signals and the control system side. Separate commons are partitioned in 16-channel groups with 500 VAC isolation separation.\u003c\/p\u003e\n\u003cp\u003eThe module operates using current sink transistor outputs intended for external 24 VDC field loads. OFF-state leakage is limited to 0.1 mA, reducing unintended field-side energization during inactive states. Output transition handling supports pulse-driven discrete control sequences with programmable timing resolution beginning at 8 ms intervals.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the ADV551-P00\/D5A00 support hot swapping during controller operation?\u003c\/strong\u003e\u003cbr\u003eA: The provided specification does not explicitly define online insertion or hot-swap capability. Standard practice is to isolate field power and follow Yokogawa controller maintenance procedures before module replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What field wiring interfaces are supported by this module?\u003c\/strong\u003e\u003cbr\u003eA: The module supports pressure clamp terminal connections, dedicated AKB331 cable assemblies, and MIL connector cable interfaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How are output commons electrically separated?\u003c\/strong\u003e\u003cbr\u003eA: Output commons are isolated in groups of 16 channels with 500 VAC withstand separation between commons.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify external supply voltage remains within 20.4 to 26.4 VDC before energizing field outputs.\u003c\/li\u003e\n\u003cli\u003eRoute output wiring separately from analog signal cables to minimize inductive switching interference.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shield grounding at a single control cabinet grounding point to avoid circulating ground current loops.\u003c\/li\u003e\n\u003cli\u003eConfirm field load current does not exceed 100 mA per channel under maximum supply conditions.\u003c\/li\u003e\n\u003cli\u003eMaintain correct polarity on current sink output circuits during terminal installation.\u003c\/li\u003e\n\u003cli\u003eInspect pressure clamp terminal retention force after field vibration exposure or maintenance activity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44146277875800,"sku":"ADV551-P00\/D5A00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ADV551-P00D5A00.jpg?v=1779847544","url":"https:\/\/www.industriaxplc.com\/products\/adv551-p00-d5a00-yokogawa-digital-output-module-32-channels","provider":"IndustriaX Limited","version":"1.0","type":"link"}