{"product_id":"adv169-p50-yokogawa-digital-input-module-new-original-stock","title":"ADV169-P50 Yokogawa Digital Input Module | New \u0026 Original Stock","description":"\u003ch1\u003eYokogawa ADV169-P50 Digital Input Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for contact status signal acquisition in CENTUM and related DCS backplane architectures, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADV169-P50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eADV169\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Input Module) provides direct physical\/electrical execution. The module accepts 64-channel discrete input signals and transfers field status conditions through transistor contact output logic with isolated channel handling.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eModel Segment\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV169\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module base model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-P50\u003c\/td\u003e\n\u003ctd\u003eFactory-defined suffix variant for module configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV169-P50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e64-channel input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal OFF State\u003c\/td\u003e\n\u003ctd\u003e100 kOhm or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal ON State\u003c\/td\u003e\n\u003ctd\u003e200 Ohm or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Response Time\u003c\/td\u003e\n\u003ctd\u003e8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eTransistor contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e16 ms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd\u003eIsolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePushbutton Input Function\u003c\/td\u003e\n\u003ctd\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e800 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eControl unit installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC backplane supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eChannel Isolation and DCS Signal Handling\u003c\/h3\u003e\n\u003cp\u003eThe ADV169-P50 module implements channel isolation between field-side discrete status circuits and internal control processing sections. Isolation architecture reduces conductive interference transfer between adjacent input groups during simultaneous switching operations.\u003c\/p\u003e\n\u003cp\u003eThe module processes dry-contact and contactor-derived voltage status signals through threshold-based ON\/OFF resistance discrimination. OFF-state recognition occurs at 100 kOhm or higher, while ON-state recognition is executed at 200 Ohm or lower. This method supports stable discrete state interpretation within DCS cabinet wiring environments containing mixed inductive loads.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the ADV169-P50 support hot swapping during energized backplane operation?\u003c\/strong\u003e\u003cbr\u003eA: Hot-swap capability is not specified in the provided technical data. Module replacement procedures should follow the control station maintenance manual and site isolation procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of field signals can be connected to the module inputs?\u003c\/strong\u003e\u003cbr\u003eA: The module is intended for contactor voltage status signals and discrete contact-state monitoring using resistance-based ON\/OFF detection thresholds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are the input channels electrically isolated?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The module specifications indicate isolated channel construction for field signal separation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRoute discrete input wiring separately from high-current motor feeder cables and inverter output conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain shield grounding at a single cabinet-side termination point to reduce ground loop current circulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify terminal torque values according to the associated Yokogawa control cabinet documentation before energization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm 5 VDC backplane power availability and current budget before module insertion into populated racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse labeled ferrules and segregated terminal grouping for multi-channel field status circuits to simplify maintenance tracing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44143060680792,"sku":"ADV169-P50","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ADV169-P50.jpg?v=1779758141","url":"https:\/\/www.industriaxplc.com\/products\/adv169-p50-yokogawa-digital-input-module-new-original-stock","provider":"IndustriaX Limited","version":"1.0","type":"link"}