{"product_id":"adv169-p00-yokogawa-digital-i-o-modules","title":"ADV169-P00 | Yokogawa | Digital I\/O Modules","description":"\u003ch2\u003eYokogawa ADV169-P00 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for 64-channel discrete signal acquisition in CENTUM and compatible ST6 control networks, the \u003cstrong\u003eYokogawa ADV169-P00\u003c\/strong\u003e (\u003cstrong\u003eADV169\u003c\/strong\u003e Digital Input Module) provides direct physical\/electrical execution for isolated digital input processing through common-minus segmentation architecture.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode Segment\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV169\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module for compatible ST6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP\u003c\/td\u003e\n\u003ctd\u003eStandard type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eAlways 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV169-P00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e64-channel input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd\u003eCommon every 16-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Contact Rating\u003c\/td\u003e\n\u003ctd\u003e5 V DC, 20 mA minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Method\u003c\/td\u003e\n\u003ctd\u003eIsolated input groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Logic Structure\u003c\/td\u003e\n\u003ctd\u003eCommon minus side every 16-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e800 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e800 mA at 5 V DC backplane supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation Architecture\u003c\/h3\u003e\n\u003cp\u003eThe ADV169-P00 implements channel grouping with common isolation applied to each 16-channel segment. This arrangement reduces conductive propagation between discrete field signal groups during switching transitions inside distributed control system I\/O assemblies.\u003c\/p\u003e\n\u003cp\u003eThe module operates using common-minus input logic for grouped termination structures. Input circuits are intended for 5 V DC discrete contact monitoring with a minimum input contact capability of 20 mA. Segmented isolation topology assists in limiting cross-channel electrical interference during simultaneous state transitions across high-density digital input assemblies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the ADV169-P00 support per-channel isolation?\u003c\/strong\u003e\u003cbr\u003eA: No. Isolation is applied per 16-channel common group rather than individually per input point.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What input signal level is required for field contacts connected to the module?\u003c\/strong\u003e\u003cbr\u003eA: The specified input contact rating is 5 V DC with a minimum current capability of 20 mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What installation consideration applies to grouped common-minus inputs?\u003c\/strong\u003e\u003cbr\u003eA: Field wiring should maintain segregation between each 16-channel common group to prevent shared return path interference and unintended signal propagation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify 5 V DC input compatibility before connecting dry-contact or transistor output field devices.\u003c\/li\u003e\n\u003cli\u003eMaintain shield grounding at a single designated cabinet grounding point to reduce common return noise coupling.\u003c\/li\u003e\n\u003cli\u003eRoute digital input cabling separately from high-current motor or inverter conductors.\u003c\/li\u003e\n\u003cli\u003eConfirm correct common-minus polarity assignment before energizing field terminations.\u003c\/li\u003e\n\u003cli\u003eAvoid mixing independent external commons across the same 16-channel isolation group.\u003c\/li\u003e\n\u003cli\u003eInspect backplane connector seating fully before applying system power to the module rack.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44146234490968,"sku":"ADV169-P00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ADV169-P00-2.jpg?v=1779847369","url":"https:\/\/www.industriaxplc.com\/products\/adv169-p00-yokogawa-digital-i-o-modules","provider":"IndustriaX Limited","version":"1.0","type":"link"}