{"product_id":"adv151-p00-d5a00-yokogawa-digital-input-module-fio-system","title":"ADV151-P00\/D5A00 Yokogawa Digital Input Module FIO System","description":"\u003ch2\u003eYokogawa ADV151-P00\/D5A00 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for ON\/OFF discrete signal acquisition in FIO-based distributed I\/O architectures, the \u003cstrong\u003eYokogawa ADV151-P00\/D5A00\u003c\/strong\u003e (\u003cstrong\u003eADV151\u003c\/strong\u003e Digital Input Module) provides direct electrical execution of 24 VDC field input conditioning within Yokogawa field control station environments.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eADV151: Base model digital input module, 32-channel architecture\u003c\/li\u003e\n\u003cli\u003e-P00: Standard hardware configuration variant\u003c\/li\u003e\n\u003cli\u003e\/D5A00: Interface adapter for 32-channel digital input coupling with ATD5A-00 cable interface system\u003cbr\u003eNo additional structured sub-variants are defined in manufacturer documentation beyond these designations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa ADV151-P00\/D5A00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e-20 degC to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e32-channel digital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e24 VDC ON\/OFF discrete signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eYokogawa FIO system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eDual redundant configuration supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-system electrical isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eYokogawa FIO Channel Isolation \u0026amp; Field Signal Conditioning\u003c\/h2\u003e\n\u003cp\u003eThe ADV151 series implements channel isolation architecture typical of Yokogawa field control I\/O subsystems. Each input channel is electrically isolated from the host control layer to reduce ground loop propagation and improve signal integrity in high-density wiring environments. The module interfaces with FIO backplane infrastructure, enabling structured field signal aggregation into the distributed control system (DCS) environment.\u003c\/p\u003e\n\u003cp\u003eSignal conditioning is optimized for 24 VDC ON\/OFF logic detection, with internal circuitry designed to stabilize input recognition under industrial switching noise conditions. Dual redundancy capability allows paired module deployment within fault-tolerant I\/O node configurations, supporting continuous operation during module-level maintenance or failure scenarios.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the ADV151-P00\/D5A00 operate in redundant I\/O configurations?\u003cbr\u003eA: Yes. The module supports dual redundant architecture when deployed in Yokogawa FIO redundant node setups.\u003c\/p\u003e\n\u003cp\u003eQ: What type of field signals are accepted at the input channels?\u003cbr\u003eA: The module is designed for 24 VDC discrete ON\/OFF digital input signals only.\u003c\/p\u003e\n\u003cp\u003eQ: Does each channel share a common reference potential?\u003cbr\u003eA: No. The design provides electrical isolation to minimize channel interaction and ground loop coupling.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eField wiring shall follow standard 24 VDC discrete signal practices using shielded twisted pair conductors where applicable. Shield termination should be performed at the designated grounding point of the cabinet side only to avoid circulating ground currents. Maintain separation between digital input wiring and power conductors to reduce electromagnetic coupling.\u003c\/p\u003e\n\u003cp\u003eEnsure correct mating of the D5A00 adapter interface with the ATD5A-00 cable assembly before energizing the FIO node. Module insertion into the FIO base unit must be performed with power removed unless the system supports hot-swap under controlled maintenance procedures defined by the control system configuration.\u003c\/p\u003e\n\u003cp\u003eTerminal tightening must comply with manufacturer-specified torque standards for field wiring blocks to ensure stable contact resistance under vibration conditions.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44146422087768,"sku":"ADV151-P00\/D5A00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ADV151-P00D5A00-3.jpg?v=1779848535","url":"https:\/\/www.industriaxplc.com\/products\/adv151-p00-d5a00-yokogawa-digital-input-module-fio-system","provider":"IndustriaX Limited","version":"1.0","type":"link"}