{"product_id":"adv142-p03-yokogawa-ac-digital-input-module-new-original-stock","title":"ADV142-P03 Yokogawa AC Digital Input Module | New \u0026 Original Stock","description":"\u003ch1\u003eYokogawa ADV142-P03 AC Digital Input Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for AC discrete signal acquisition in CENTUM VP systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADV142-P03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eADV142\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC Digital Input Module) provides direct physical\/electrical execution. The module processes 200 to 240 VAC field inputs through 16 isolated channels with common isolation every 8 channels and supports ON\/OFF state monitoring together with pushbutton edge counting functions.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eModel Segment\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV142\u003c\/td\u003e\n\u003ctd\u003eAC Digital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-P03\u003c\/td\u003e\n\u003ctd\u003e200 to 240 VAC input specification variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV142-P03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAC Digital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eAC digital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd\u003eCommon isolation every 8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e200 to 240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON Voltage (Peak)\u003c\/td\u003e\n\u003ctd\u003e160 VAC (226 V peak) to 264 VAC (373 V peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF Voltage (Peak)\u003c\/td\u003e\n\u003ctd\u003e40 VAC (56 V peak) maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current (Typical)\u003c\/td\u003e\n\u003ctd\u003e6.2 mA per channel at 240 V \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current (Maximum)\u003c\/td\u003e\n\u003ctd\u003e9.3 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Response Time\u003c\/td\u003e\n\u003ctd\u003e160 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum ON Detection Time\u003c\/td\u003e\n\u003ctd\u003e200 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum ON\/OFF Cycle\u003c\/td\u003e\n\u003ctd\u003e2.5 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kVAC for 1 minute (signal to system), 1.35 kVAC between commons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e500 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eDual redundant configuration supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eChannel Isolation and DCS Signal Handling\u003c\/h3\u003e\n\u003cp\u003eThe ADV142-P03 implements channel grouping isolation every 8 channels to separate high-voltage AC field signals from internal control circuitry within CENTUM VP I\/O architectures. The module supports discrete status acquisition for 200 to 240 VAC process contacts while maintaining electrical separation between isolated commons.\u003c\/p\u003e\n\u003cp\u003eInput processing includes ON\/OFF state validation and pushbutton pulse detection for low-frequency transition monitoring up to 2.5 Hz. Isolation barriers are designed for direct integration into distributed process control cabinets where mixed-voltage field termination and grounded AC sensing loops are present.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ADV142-P03 support redundant I\/O operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports dual redundant configuration within compatible Yokogawa CENTUM VP system architectures.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module detect short-duration pulse transitions from pushbuttons?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The specified minimum ON detection time for pushbutton input processing is 200 ms, with a maximum ON\/OFF cycle rate of 2.5 Hz.\u003c\/p\u003e\n\u003cp\u003eQ: What isolation structure is used for the input channels?\u003c\/p\u003e\n\u003cp\u003eA: The module provides common isolation for every 8 input channels. Signal-to-system dielectric withstand voltage is rated at 2 kVAC for 1 minute.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify field input voltage before energizing terminal circuits. The module is intended for 200 to 240 VAC discrete input signals only.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain separation between AC input wiring and low-level analog or communication cables inside the cabinet to reduce induced noise coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect cable shields according to plant grounding standards and terminate shields at a single grounding reference point where applicable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm backplane seating and locking engagement before applying system power in redundant node configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse properly rated terminal blocks and insulation spacing for high-voltage AC field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePerform insulation resistance checks on field loops prior to module insertion when commissioning new installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44143037513816,"sku":"ADV142-P03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ADV142-P03-2.jpg?v=1779757636","url":"https:\/\/www.industriaxplc.com\/products\/adv142-p03-yokogawa-ac-digital-input-module-new-original-stock","provider":"IndustriaX Limited","version":"1.0","type":"link"}