{"product_id":"abb-tu818-compact-module-termination-unit","title":"ABB TU818 Compact Module Termination Unit","description":"\u003ch2\u003eABB TU818 Compact Module Termination Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for signal termination and field wiring distribution, the \u003cstrong\u003eABB 3BSE069209R1\u003c\/strong\u003e (\u003cstrong\u003eTU818\u003c\/strong\u003e Compact Module Termination Unit) provides physical termination for 1x32 or 2x16 signal arrangements. The unit is specified for 50 V operation and uses a compact 64 mm x 170 mm x 58.5 mm mechanical format.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTU818\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSE069209R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModule Termination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Description\u003c\/td\u003e\n\u003ctd\u003eTU818 Compact MTU, 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Terminals\u003c\/td\u003e\n\u003ctd\u003e1x32 or 2x16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e64 mm D x 170 mm H x 58.5 mm W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003ctd\u003eEU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003e5, Small Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSVHC\u003c\/td\u003e\n\u003ctd\u003eNone present according to supplied SCIP information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e853710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd\u003e85371098\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Industrial Control and I\/O Termination\u003c\/h3\u003e\n\u003cp\u003eThe TU818 provides a compact physical termination interface for field signal wiring. Its terminal arrangement supports either one 32-signal configuration or two 16-signal configurations.\u003c\/p\u003e\n\u003cp\u003eBecause the supplied documentation identifies the unit as a Module Termination Unit, the TU818 should not be treated as an active I\/O processor or communication interface. Instead, it provides the termination hardware required for the connected signal circuits.\u003c\/p\u003e\n\u003cp\u003eThe 50 V specification defines the stated voltage class for the termination unit. Therefore, connected field circuits must remain within the applicable electrical limits of the complete I\/O assembly and associated wiring.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the TU818 process or convert field signals?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The supplied specification identifies the TU818 as a Module Termination Unit. It provides signal termination rather than signal processing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many signal terminals does the TU818 support?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The unit supports 1x32 signal terminals or 2x16 signal terminals, according to the ABB catalog description.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the TU818 a powered electronic I\/O module?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied data does not identify an internal power consumption value. The TU818 is specified as a Module Termination Unit rather than an active signal-processing module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the TU818 according to the mechanical arrangement of the associated ABB I\/O assembly.\u003c\/li\u003e\n\u003cli\u003eVerify the terminal configuration before connecting field wiring, using the required 1x32 or 2x16 arrangement.\u003c\/li\u003e\n\u003cli\u003eConfirm that connected circuits comply with the stated 50 V voltage specification.\u003c\/li\u003e\n\u003cli\u003eRoute signal wiring separately from high-current or high-voltage conductors where the installation design requires noise reduction.\u003c\/li\u003e\n\u003cli\u003eMaintain correct terminal identification throughout installation and commissioning.\u003c\/li\u003e\n\u003cli\u003eApply the plant grounding and shield termination practices specified for the complete control-system installation.\u003c\/li\u003e\n\u003cli\u003eInspect terminal connections for secure mechanical engagement before energizing the associated circuits.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44595711443032,"sku":"TU818V1 3BSE069209R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TU818V1-3BSE069209R1-3_1200x1200_bf148913-7ca4-433c-bdbb-18165a9b7ff1.jpg?v=1786703223","url":"https:\/\/www.industriaxplc.com\/products\/abb-tu818-compact-module-termination-unit","provider":"IndustriaX Limited","version":"1.0","type":"link"}