{"product_id":"abb-tk811v150-s800-modulebus-optical-cable","title":"ABB TK811V150 S800 ModuleBus Optical Cable","description":"\u003ch2\u003eABB TK811V150 S800 ModuleBus Optical Cable\u003c\/h2\u003e\n\u003cp\u003eConfigured for optical ModuleBus communication in ABB S800 systems, the \u003cstrong\u003eABB TK811V150\u003c\/strong\u003e (\u003cstrong\u003eTK811V150\u003c\/strong\u003e Duplex Plastic Optical Fiber Cable) provides a 15 m physical optical link between compatible ModuleBus nodes.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK811V150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSC950107R3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDuplex Plastic Optical Fiber Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eOptical ModuleBus connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Type\u003c\/td\u003e\n\u003ctd\u003ePlastic Optical Fiber (POF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e15 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Configuration\u003c\/td\u003e\n\u003ctd\u003eDuplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003ePrefabricated connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Diameter\u003c\/td\u003e\n\u003ctd\u003e5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.125 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15 m cable length; 5 mm cable diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanics\u003c\/td\u003e\n\u003ctd\u003eS800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOptical ModuleBus Communication\u003c\/h3\u003e\n\u003cp\u003eThe TK811V150 carries ModuleBus communication through a duplex plastic optical fiber path. Therefore, the communication link uses optical transmission rather than a copper electrical signal path.\u003c\/p\u003e\n\u003cp\u003eThe POF construction provides electrical isolation between connected nodes. In addition, the optical path does not form a conductive signal path for electromagnetic interference. Consequently, the cable can separate the communication medium from electrical noise sources associated with industrial control wiring.\u003c\/p\u003e\n\u003cp\u003eThe 15 m cable length defines the physical connection supplied by this model. Furthermore, the prefabricated construction reduces field termination work and preserves the specified connector arrangement.\u003c\/p\u003e\n\u003cp\u003eFor S800 installations, the cable functions as a physical ModuleBus interconnection component. However, the supplied data does not specify communication velocity, optical attenuation, wavelength, or receiver sensitivity, so these values should not be inferred from the model number.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the TK811V150 require an electrical power connection?\u003c\/p\u003e\n\u003cp\u003eA: No. The TK811V150 is a passive optical cable and has no specified power consumption.\u003c\/p\u003e\n\u003cp\u003eQ: What is the physical cable length?\u003c\/p\u003e\n\u003cp\u003eA: The TK811V150 has a specified cable length of 15 m.\u003c\/p\u003e\n\u003cp\u003eQ: Can the cable length or optical performance be extended by field splicing?\u003c\/p\u003e\n\u003cp\u003eA: The supplied data identifies the product as a prefabricated cable. It does not specify field splicing procedures or permitted modifications. Therefore, installation should retain the supplied cable and connector configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify the complete ABB part number, \u003cstrong\u003e3BSC950107R3\u003c\/strong\u003e, before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm that both connected devices support the required optical ModuleBus interface.\u003c\/li\u003e\n\u003cli\u003eRoute the cable away from mechanical pinch points, sharp edges, and excessive bending.\u003c\/li\u003e\n\u003cli\u003eDo not pull the cable by its optical connectors during installation.\u003c\/li\u003e\n\u003cli\u003eKeep connector interfaces clean and protected from dust before mating.\u003c\/li\u003e\n\u003cli\u003eMaintain the factory-installed connector configuration unless ABB documentation explicitly permits modification.\u003c\/li\u003e\n\u003cli\u003eAvoid routing practices that place continuous mechanical stress on the fiber cable.\u003c\/li\u003e\n\u003cli\u003eAfter installation, verify that both optical connectors are fully seated and mechanically latched.\u003c\/li\u003e\n\u003cli\u003eIf communication faults occur, inspect connector seating, cable routing, visible damage, and fiber continuity before replacing system hardware.\u003c\/li\u003e\n\u003cli\u003eDo not assign an operating temperature, minimum bend radius, attenuation, or optical transmission limit unless the applicable ABB installation documentation specifies the value\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612639621208,"sku":"TK811V150 3BSC950107R3","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TK811V150-3BSC950107R3-3_1200x1200_607fe9d4-a81c-4057-8ae4-5b544ce0bbbd.jpg?v=1786959329","url":"https:\/\/www.industriaxplc.com\/products\/abb-tk811v150-s800-modulebus-optical-cable","provider":"IndustriaX Limited","version":"1.0","type":"link"}