{"product_id":"abb-tas01-turbine-auto-synchronization-i-o-module","title":"ABB TAS01 Turbine Auto-Synchronization I\/O Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTAS01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dedicated turbine generator synchronization module developed for ABB Harmony Rack, Symphony Plus, and Bailey Infi-90 control platforms. It performs precise automatic synchronization between a turbine-driven generator and the power grid by continuously analyzing voltage, frequency, and phase angle conditions.\u003c\/p\u003e\n\u003cp\u003eDesigned for critical power applications, this module eliminates the need for manual synchronization procedures and significantly reduces the risk of out-of-phase breaker closure. Its fast processing capability ensures rapid response during synchronization events, contributing to improved system safety and operational consistency.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTAS01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis typically deployed in turbine control systems where accurate grid connection and generator protection are essential.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Functional Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic matching of generator and grid parameters prior to breaker closure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous monitoring of phase angle, voltage magnitude, and frequency deviation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput control signals for synchronization and breaker operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed decision logic for real-time synchronization events\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration within ABB distributed control system architectures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTAS01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManufacturer: ABB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule Type: Turbine Auto-Synchronization I\/O Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation: Rack-mounted (Harmony \/ Symphony \/ Infi-90 systems)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInput and Output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog Inputs: 8 channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports voltage, current, frequency, and phase measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eDigital Outputs: 4 channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUsed for synchronization commands and control triggers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSynchronization Performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePhase Accuracy: ±0.1°\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Accuracy: ±0.01 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResponse Time: ≤ 10 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupply Voltage:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e24 V DC (standard configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional support for 110 \/ 230 V AC depending on system setup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003ePower Consumption: approximately 5 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions (approximate):\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eLength: 297–300 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWidth: 175 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeight: 35–36 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eAlternative compact format reference: 17.8 × 5.1 × 2.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.75 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Method: Standard ABB rack system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: –25 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: –40 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental Classification: WEEE Category 5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eABB Harmony Rack systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eABB Symphony Plus DCS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBailey Infi-90 and Infi-90 Open control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam and gas turbine generator synchronization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower plant grid connection control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGenerator protection and startup sequencing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial cogeneration systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the TAS01 module control during synchronization?\u003c\/strong\u003e\u003cbr\u003eIt evaluates phase angle, voltage, and frequency differences between the generator and grid, then issues a controlled closing command when conditions are within tolerance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan TAS01 be used in redundant control architectures?\u003c\/strong\u003e\u003cbr\u003eYes, it is compatible with redundant DCS configurations, enhancing system reliability in critical power applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs manual synchronization still required?\u003c\/strong\u003e\u003cbr\u003eNo, the module automates the entire synchronization process, though manual override may be available depending on system design.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44046158069848,"sku":"TAS01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TAS01.jpg?v=1777371323","url":"https:\/\/www.industriaxplc.com\/products\/abb-tas01-turbine-auto-synchronization-i-o-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}