{"product_id":"abb-symphony-infi-90-imasi13-analog-input-slave-module","title":"ABB Symphony INFI-90 IMASI13 Analog Input Slave Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB IMASI13\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a multi-channel analog input module developed for the Symphony INFI-90 distributed control platform. It is responsible for collecting analog field signals, performing signal conditioning, and converting them into digital values for processing by the control system.\u003c\/p\u003e\n\u003cp\u003eDesigned for precision and reliability, this module supports a wide range of industrial measurement inputs and ensures stable acquisition even in electrically noisy environments. It is commonly deployed in critical process industries requiring consistent and accurate signal monitoring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAccepts multiple analog signal types from field instrumentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePerforms signal conditioning including filtering and scaling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConverts analog signals into digital data using high-resolution A\/D conversion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides isolation to reduce interference and protect system integrity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReports module and channel diagnostics to the control processor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrates seamlessly into INFI-90 I\/O architectures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane Supply: 5 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Consumption: Approximately 6–8 VA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Signal Types: Configurable analog current and voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInput Configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNumber of Channels: 16 independently configurable channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent Input Range: 4–20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMillivolt Input Range: –100 mV to +100 mV \/ 0 to 100 mV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Isolation: Channel-to-channel and channel-to-system isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eA\/D Converter Resolution: Typically 12–16 bit class\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Filtering: Combined hardware and digital filtering\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement Accuracy: Industrial-grade precision for process control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSystem Bus: INFI-90 I\/O communication bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData Handling: Buffered and synchronized data transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostics: Continuous monitoring of channel status and module health\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: –40°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity: 5% to 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 7.0 × 2.0 × 13.0 in (17.8 × 5.1 × 33.0 cm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.4 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eForm Factor: Eurocard module for INFI-90 systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Compatible with Module Mounting Unit (MMU)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFront Panel Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModule status indicator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChannel activity\/status LEDs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdentification labeling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB IMASI13\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis used in process environments where accurate analog data acquisition is essential:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation plants including thermal and nuclear facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil refining and petrochemical processing units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePulp and paper manufacturing systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeavy industrial automation with distributed control requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat types of signals can the IMASI13 accept?\u003c\/strong\u003e\u003cbr\u003eIt supports standard industrial analog signals such as 4–20 mA and low-level millivolt inputs, depending on configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many input channels are available?\u003c\/strong\u003e\u003cbr\u003eThe module provides 16 independently configurable input channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the module suitable for noisy environments?\u003c\/strong\u003e\u003cbr\u003eYes, built-in filtering and isolation features ensure stable performance in high-interference conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does it communicate with the control system?\u003c\/strong\u003e\u003cbr\u003eIt uses the INFI-90 I\/O bus with buffered and synchronized data transfer to maintain real-time performance.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44054970990680,"sku":"IMASI13","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IMASI131.jpg?v=1777539476","url":"https:\/\/www.industriaxplc.com\/products\/abb-symphony-infi-90-imasi13-analog-input-slave-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}