{"product_id":"abb-ntam01-analog-master-termination-unit-infi-90-dcs","title":"ABB NTAM01 Analog Master Termination Unit INFI 90 DCS","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNTAM01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Master Termination Unit is a passive field interface assembly developed for the Bailey INFI 90 Distributed Control System. The unit is engineered to organize, terminate, and distribute analog process signals between field instrumentation and INFI 90 control modules.\u003c\/p\u003e\n\u003cp\u003eDesigned for stable analog signal management, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNTAM01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports calibration routing, cold-junction compensation transfer, and standardized field wiring arrangements. Its rack-mounted construction simplifies cabinet integration while maintaining reliable signal integrity in continuous process environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePassive analog signal termination architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with ABB Bailey INFI 90 DCS platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports voltage and current analog signal transmission\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated cold-junction compensation reference handling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration signal routing support through IMAMM03 modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterfaces with multiple analog input termination assemblies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRack-mounted format for NFTP01 field termination panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eScrew terminal wiring for secure industrial connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for long-term operation in process automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNTAM01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Master Termination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eABB Bailey INFI 90 DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Function\u003c\/td\u003e\n\u003ctd\u003eAnalog signal termination and routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Signal Types\u003c\/td\u003e\n\u003ctd\u003e0–10 V, 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Analog Channels\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Analog Input Units\u003c\/td\u003e\n\u003ctd\u003eUp to 4 × NTAI02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Indicator Stations\u003c\/td\u003e\n\u003ctd\u003eUp to 4 × NDIS01 \/ NDISe1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Routing\u003c\/td\u003e\n\u003ctd\u003eVia IMAMM03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold-Junction Compensation\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eRack Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel Compatibility\u003c\/td\u003e\n\u003ctd\u003eNFTP01 Field Termination Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew Terminal Blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e+24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 17 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e7.0 × 1.0 × 8.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNTAM01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely installed in process industries requiring stable analog signal termination and centralized wiring management, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePetrochemical facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater treatment plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous manufacturing lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess automation cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDistributed control environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNTAM01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etermination unit is commonly paired with ABB INFI 90 analog input modules and master control assemblies. Its design enables simplified maintenance access and organized field signal distribution inside control cabinets.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat is the main purpose of the NTAM01?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNTAM01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides analog field signal termination, routing, and calibration support for ABB Bailey INFI 90 systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes the NTAM01 actively process signals?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. The unit is a passive termination assembly designed for signal distribution and interface connectivity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhich analog signals are supported?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module supports standard industrial analog signals including 0–10 V and 4–20 mA.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan the NTAM01 support multiple input units?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. The unit can interface with up to four NTAI02 analog input units and several digital indicator\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44087674568792,"sku":"NTAM01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/NTAM01.jpg?v=1778310255","url":"https:\/\/www.industriaxplc.com\/products\/abb-ntam01-analog-master-termination-unit-infi-90-dcs","provider":"IndustriaX Limited","version":"1.0","type":"link"}