{"product_id":"abb-innpm11-network-processing-communication-module","title":"ABB INNPM11 Network Processing Communication Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB INNPM11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNetwork Processing Module is a core communication component used within ABB INFI-90 \/ Symphony distributed control architectures. It functions as a high-speed message processor responsible for data exchange between Controlway, Module Bus, and the INFI-NET network layer.\u003c\/p\u003e\n\u003cp\u003eDesigned by\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eABB\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor deterministic control environments, this module ensures synchronized information flow between controller-level operations and plant-wide communication infrastructure.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eINNPM11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates in conjunction with the INNIS01 interface module to establish a complete communication pathway between process control units and the INFI-NET backbone. It manages cyclic data, exception reporting, system polling, and time synchronization across distributed nodes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePlatform: ABB INFI-90 \/ Symphony DCS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFunction: Network processing and protocol handling module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommunication layers: Controlway, Module Bus, INFI-NET\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNetwork role: Message routing and synchronization processor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eControlway speed: 1 Mbaud\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule Bus speed: 83.3 kbaud\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eINFI-NET: High-speed serial deterministic data highway\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupported messaging: Broadcast, multicast, exception reporting, polling, time sync\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProcessing \u0026amp; Memory\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRAM: 512 KB onboard memory\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eROM: 256 KB firmware storage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcessing function: Real-time message scheduling and routing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupply voltage: +5 VDC (backplane powered)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower consumption: approx. 10 W (2 A typical load)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsolation: Electrical separation between network and system backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Design\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModule type: INFI-90 standard plug-in card\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 27.9 cm × 7.6 cm × 5.1 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.2 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation: Standard ABB rack slot configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCooling: Passive convection within chassis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Role in System Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eINNPM11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the central message handler for inter-layer communication inside INFI-90 systems. It ensures:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDeterministic routing of control and process data\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time synchronization between distributed controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eException-based data transmission for efficiency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStable communication across redundant network topologies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCoordination between Controlway-level and plant-level networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDistributed process control system communication backbone\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time controller coordination in industrial plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData synchronization between HMI and controller networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration layer for SCADA and engineering stations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-availability automation system architectures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the primary role of INNPM11?\u003c\/strong\u003e\u003cbr\u003eIt processes and routes communication between Controlway, Module Bus, and INFI-NET networks in INFI-90 systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does INNPM11 support redundancy?\u003c\/strong\u003e\u003cbr\u003eYes, it is designed to operate within redundant INFI-NET system configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is it compatible with modern SCADA systems?\u003c\/strong\u003e\u003cbr\u003eIt can interface through gateway modules for SCADA and historian integration within legacy ABB infrastructures.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44088405295192,"sku":"INNPM11","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/INNPM112.jpg?v=1778320297","url":"https:\/\/www.industriaxplc.com\/products\/abb-innpm11-network-processing-communication-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}