{"product_id":"abb-inict03-computer-network-interface-module","title":"ABB INICT03 Computer Network Interface Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB INICT03A INICT03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule is a communication interface designed for ABB INFI-90 \/ Symphony distributed control systems. It connects the INFI-NET control network with external computer systems including operator workstations, engineering stations, and data servers.\u003c\/p\u003e\n\u003cp\u003eIt is installed in an ABB N-Module rack and functions as a central data exchange node, enabling plant-wide access to real-time process information and system status.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Function Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis module operates as a network bridge between the INFI-NET token-passing control network and host computing platforms. It supports continuous and synchronized data exchange across industrial automation layers.\u003c\/p\u003e\n\u003cp\u003eMain functions include\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTransfer of real-time process values from controllers to host systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTransmission of alarms and event messages for supervisory monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery of system diagnostics and status information\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBidirectional communication for configuration and control support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is commonly used in SCADA systems, historians, and engineering environments where reliable data access is required.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCommunication Interface\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNetwork Type: INFI-NET redundant token-passing architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommunication Mode: Bidirectional data transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData Types: Process values, alarms, events, diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem Integration: HMI, SCADA, historian, engineering tools\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eElectrical Characteristics\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower Supply: +5 VDC via N-Module backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Consumption: Approximately 10 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMechanical Design\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModule Type: ABB N-Module plug-in card\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: INFI-90 \/ Symphony rack compatible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Type: Backplane edge connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndicators: LED status for network and module diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEnvironmental Conditions\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0°C to 60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40°C to 85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity: 5% to 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCooling: Natural convection within rack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePhysical Data\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 2.01 lbs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProvides communication bridge between control network and computer systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports redundant INFI-NET architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnables deterministic real-time data exchange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for continuous industrial operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with rack-based hot-swap configurations depending on system setup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDistributed control system integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlant monitoring and visualization systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSCADA supervisory control environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEngineering configuration stations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial data acquisition and historian systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44088256036952,"sku":"INICT03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/INICT032.jpg?v=1778318644","url":"https:\/\/www.industriaxplc.com\/products\/abb-inict03-computer-network-interface-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}