{"product_id":"abb-advant-ac800m-ci867ak01-3bse092689r1-modbus-tcp-interface-module","title":"ABB CI867AK01 3BSE092689R1 Modbus TCP Interface Module Kit","description":"\u003cp\u003eThe ABB CI867AK01 (3BSE092689R1) is a high-performance Modbus TCP communication interface module designed for the ABB AC 800M control system family. This kit includes the CI867 communication module and the required TP867 mounting base for seamless integration into the controller rack.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual RJ45 Ethernet ports supporting 10\/100 Mbps data rates.\u003c\/li\u003e\n\u003cli\u003eConfigurable as both Modbus TCP client (master) and server (slave).\u003c\/li\u003e\n\u003cli\u003eSupports cyclic and acyclic data exchange for process variables.\u003c\/li\u003e\n\u003cli\u003eCompatible with standard Modbus data types including coils, discrete inputs, and registers.\u003c\/li\u003e\n\u003cli\u003eSupports 16-bit and 32-bit register access with configurable byte\/word swapping.\u003c\/li\u003e\n\u003cli\u003eHot-swap capability allows for module replacement without requiring a system shutdown.\u003c\/li\u003e\n\u003cli\u003eIntegrates directly into the Control Builder M or Compact Control Builder engineering environment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOil and Gas: Integration of remote I\/O and field devices on offshore platforms and refineries.\u003c\/li\u003e\n\u003cli\u003ePower and Utilities: Data exchange with power meters and protection relays in water treatment and power plants.\u003c\/li\u003e\n\u003cli\u003eChemical and Petrochemical: Reliable communication bridge for third-party PLCs and variable frequency drives.\u003c\/li\u003e\n\u003cli\u003eManufacturing: Scalable connectivity for automated batch processing and high-availability systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI867AK01 (3BSE092689R1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45 (10\/100 Mbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 degC to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5-95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTypically 1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 V AC galvanic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMount the TP867 baseplate onto a standard 35 mm top-hat DIN rail.\u003c\/li\u003e\n\u003cli\u003eSlide the baseplate along the rail to engage the CEX-Bus side connector with the controller or adjacent module.\u003c\/li\u003e\n\u003cli\u003eAlign the CI867 module with the TP867 base and press firmly until the locking mechanism clicks.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the DIN rail to maintain EMI immunity.\u003c\/li\u003e\n\u003cli\u003eAlways power down the system before installing or removing modules if hot-swap procedures are not explicitly active in your specific configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the CI867AK01?\u003c\/h3\u003e\u003cp\u003eThe CI867AK01 acts as a communication bridge, allowing the ABB AC 800M controller to exchange process data with third-party Modbus TCP-compatible devices such as VFDs, motor starters, and remote I\/O stations.\u003c\/p\u003e\u003ch3\u003eDoes this module support redundancy?\u003c\/h3\u003e\u003cp\u003eYes, the CI867 supports redundant configurations, allowing for high-availability communication in critical industrial applications.\u003c\/p\u003e\u003ch3\u003eCan this module be used as a master and a slave?\u003c\/h3\u003e\u003cp\u003eYes, the module is highly flexible and can be configured to act as a Modbus TCP client (master) to poll field devices or as a server (slave) to provide data to upper-level SCADA or DCS systems.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44616391524440,"sku":"CI867AK01 3BSE092689R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_abe3520f-75d8-4b1f-afb7-a7f6bd485d5b.jpg?v=1786992188","url":"https:\/\/www.industriaxplc.com\/products\/abb-advant-ac800m-ci867ak01-3bse092689r1-modbus-tcp-interface-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}