{"product_id":"abb-07kt97-gjr5253000r0276-advant-controller-31-basic-unit","title":"ABB 07KT97 GJR5253000R0276 Advant Controller 31 Basic Unit","description":"\u003ch2\u003eABB 07KT97 GJR5253000R0276 Advant Controller 31 Basic Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for logic execution, integrated I\/O processing, counting, and serial communication in the AC31 control system, the \u003cstrong\u003eABB 07KT97 GJR5253000R0276\u003c\/strong\u003e (\u003cstrong\u003e07KT97\u003c\/strong\u003e Basic Unit) provides direct electrical execution. The unit integrates CPU processing, program and data memory, digital and analog I\/O, high-speed counters, CS31 communication, serial interfaces, and removable memory support within one PLC basic unit.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e07KT97 GJR5253000R0276\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e07KT97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAdvant Controller 31 Basic Unit \/ CPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAdvant Controller 31 (AC31)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Program Memory\u003c\/td\u003e\n\u003ctd\u003e480 kB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Data Memory\u003c\/td\u003e\n\u003ctd\u003e256 kB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Type\u003c\/td\u003e\n\u003ctd\u003eFlash EPROM \/ non-volatile RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExecution Speed\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.3 ms per 1000 instructions, based on 65% logic and 35% word instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e24 channels, 24 VDC, arranged in 3 groups of 8, electrically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e16 channels, transistor type, 24 VDC \/ 0.5 A, arranged in 2 groups of 8, isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigurable Digital I\/O\u003c\/td\u003e\n\u003ctd\u003e8 channels, individually configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e8 channels, individually configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Ranges\u003c\/td\u003e\n\u003ctd\u003e0-10 V, 0-5 V, -10 to +10 V, -5 to +5 V, 0-20 mA, 4-20 mA, Pt100, or digital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e4 channels, individually configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Ranges\u003c\/td\u003e\n\u003ctd\u003e-10 to +10 V, 0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Speed Counters\u003c\/td\u003e\n\u003ctd\u003e2 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Counter Frequency\u003c\/td\u003e\n\u003ctd\u003eUp to 50 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Bus\u003c\/td\u003e\n\u003ctd\u003e1 x CS31 system bus interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in Network Interfaces\u003c\/td\u003e\n\u003ctd\u003eEthernet \/ ARCNET, depending on specific sub-version configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM1\u003c\/td\u003e\n\u003ctd\u003eRS232 for programming, Modbus Master\/Slave, or ASCII communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM2\u003c\/td\u003e\n\u003ctd\u003eRS232 for Modbus Master\/Slave or ASCII communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Card Interface\u003c\/td\u003e\n\u003ctd\u003eSmartMedia Card \/ memory card slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Backup\u003c\/td\u003e\n\u003ctd\u003eLithium battery backup supported, including 07 LE 90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Software\u003c\/td\u003e\n\u003ctd\u003e907 AC 1131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSWEDEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eAC31 I\/O Density and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 07KT97 integrates processing functions and mixed signal I\/O within the basic unit. Consequently, the controller can execute digital logic while processing analog voltage, current, and Pt100 input signals without requiring all functions to be assigned to external modules.\u003c\/p\u003e\n\u003cp\u003eThe CS31 system bus provides the electrical communication path for decentralized I\/O expansion. Therefore, installation planning should consider controller configuration, bus topology, and connected module addressing as part of the complete AC31 system configuration.\u003c\/p\u003e\n\u003cp\u003eThe unit also uses non-volatile memory and removable memory support for program and data handling. Firmware and application compatibility should be checked against the installed controller hardware revision and the 907 AC 1131 engineering environment before loading or transferring application data.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 07KT97 analog input channels accept both voltage and current signals?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. Each analog input channel can be individually configured for specified voltage ranges, 0-20 mA, 4-20 mA, Pt100 measurement, or digital input operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are the integrated high-speed counters suitable for fast pulse signals?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The unit provides two hardware counter channels with operation up to 50 kHz. Signal wiring and electrical noise control should be considered when connecting high-frequency pulse sources.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 07KT97 support external I\/O expansion?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The integrated CS31 system bus interface supports decentralized I\/O expansion within the Advant Controller 31 system architecture.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 07KT97 in accordance with the applicable AC31 mounting and electrical installation requirements. Verify the 24 VDC supply polarity and provide suitable upstream circuit protection before energizing the controller.\u003c\/p\u003e\n\u003cp\u003eRoute analog, counter, and communication wiring separately from high-current switching conductors. In addition, use appropriate shielded cables where required by the connected signal type and ground cable shields according to the overall control cabinet grounding concept.\u003c\/p\u003e\n\u003cp\u003eBefore connecting external I\/O, confirm the configured electrical range for each channel. For example, do not connect a 4-20 mA loop to a channel configured for an incompatible voltage range.\u003c\/p\u003e\n\u003cp\u003eCheck RS232 communication parameters and protocol settings before connecting programming equipment or Modbus devices. Likewise, verify CS31 bus wiring and module configuration before commissioning decentralized I\/O.\u003c\/p\u003e\n\u003cp\u003eDo not insert or remove wiring connections while the installation is energized unless the applicable system documentation explicitly permits the procedure. Finally, back up the application and verify battery-supported memory requirements before replacing or servicing the controller.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44685738541144,"sku":"07KT97 GJR5253000R0276","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/07KT97-GJR5253000R0276-3_1200x1200_8810c948-1069-44ae-8146-1c2a1aa4a7ba.jpg?v=1788160235","url":"https:\/\/www.industriaxplc.com\/products\/abb-07kt97-gjr5253000r0276-advant-controller-31-basic-unit","provider":"IndustriaX Limited","version":"1.0","type":"link"}