{"product_id":"6gk11052ae00-siemens-simatic-net-optical-switch-module","title":"Siemens 6GK1105-2AE00 SIMATIC NET Optical Switch Module OSM TP22","description":"\u003cp\u003eThe Siemens SIMATIC NET OSM TP22 (6GK1105-2AE00) is a robust industrial optical switch module designed to provide reliable, high-availability connectivity within Industrial Ethernet networks. This module functions as a critical backbone component, utilizing integrated redundancy management to ensure deterministic data transmission and rapid recovery in the event of network segment failures.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Management:\u003c\/strong\u003e Built-in Redundancy Manager (RM) capabilities allow for sub-millisecond reconfiguration of ring topologies, preventing downtime during link interruptions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Media Support:\u003c\/strong\u003e Equipped with two 100 Mbit\/s fiber optic ports for long-range, EMI-immune backbone communication and two 10\/100 Mbit\/s RJ45 ports for standard local device connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated I\/O:\u003c\/strong\u003e Features four digital inputs for monitoring field-level binary signals and a signaling contact relay to provide immediate hardware-level fault notification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Reliability:\u003c\/strong\u003e Designed with redundant 24 VDC power inputs to ensure continuous operation even if one power source fails.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe OSM TP22 is widely utilized in demanding industrial environments where network stability is paramount. Common applications include petrochemical processing, power generation control systems, and automated mining operations, where it serves as a central node for maintaining communication integrity across distributed automation equipment.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6GK1105-2AE00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens SIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Optic Ports\u003c\/td\u003e\n\u003ctd\u003e2 x 100 Mbit\/s (Multi-mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 Ports\u003c\/td\u003e\n\u003ctd\u003e2 x 10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling Contact\u003c\/td\u003e\n\u003ctd\u003e1 x Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (18-32 VDC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the module is mounted securely in a clean, dry cabinet with adequate ventilation to maintain operating temperatures below 60 deg C.\u003c\/li\u003e\n\u003cli\u003eFollow standard ESD (Electrostatic Discharge) procedures when handling the module to prevent internal component damage.\u003c\/li\u003e\n\u003cli\u003eEnsure all power connections are wired to the dual terminal blocks to utilize the redundant power supply functionality.\u003c\/li\u003e\n\u003cli\u003eVerify that fiber optic cables are cleaned properly before insertion to maintain signal integrity; avoid sharp bends in the cable path.\u003c\/li\u003e\n\u003cli\u003eAlways power down the system before inserting or removing the module from the rail to prevent electrical arcing or configuration errors.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the redundancy manager in this module?\u003c\/strong\u003e The redundancy manager monitors the network ring topology and, upon detecting a link failure, automatically reconfigures the data path to ensure the network remains operational without significant interruption.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this module be used in high-EMI environments?\u003c\/strong\u003e Yes, the fiber optic ports provide complete galvanic isolation, making the module ideal for environments with high electromagnetic interference or significant ground potential differences.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44727599628376,"sku":"6GK1105-2AE00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_f76169a5-659f-4f53-87d6-4567c469f7c3.jpg?v=1788576528","url":"https:\/\/www.industriaxplc.com\/products\/6gk11052ae00-siemens-simatic-net-optical-switch-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}