{"product_id":"6es7134-4gb01-0ab0-siemens-simatic-dp-ai-module","title":"Siemens 6ES7134-4GB01-0AB0 SIMATIC DP Analog Input Module","description":"\u003cp\u003eThe Siemens 6ES7134-4GB01-0AB0 is a standard electronic analog input module designed for the SIMATIC ET 200S distributed I\/O system. This module provides two channels for processing 4-20 mA current signals from 2-wire transducers, offering a resolution of 13 bits and a cycle time of 65 ms per channel. Its compact 15 mm width makes it an efficient solution for space-constrained control cabinets in various industrial automation environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel analog input for 2-wire current loop transducers.\u003c\/li\u003e\n\u003cli\u003e13-bit resolution with a 65 ms conversion cycle per channel.\u003c\/li\u003e\n\u003cli\u003eIntegrated group fault (SF) LED for rapid diagnostics.\u003c\/li\u003e\n\u003cli\u003eCompact 15 mm module width for high-density ET 200S configurations.\u003c\/li\u003e\n\u003cli\u003eBuilt-in reverse polarity protection with a destruction limit of 35 mA per channel.\u003c\/li\u003e\n\u003cli\u003eParameterizable smoothing and filtering functions.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProcess automation for water and wastewater treatment facilities.\u003c\/li\u003e\n\u003cli\u003eChemical and petrochemical processing plants requiring remote signal monitoring.\u003c\/li\u003e\n\u003cli\u003ePressure and flow tracking using hydrostatic, electromagnetic, or vortex sensors.\u003c\/li\u003e\n\u003cli\u003eLevel measurement systems for industrial storage tanks.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6ES7134-4GB01-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA (2-wire transducer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e13-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCycle Time\u003c\/td\u003e\n\u003ctd\u003e65 ms per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage (DC)\u003c\/td\u003e\n\u003ctd\u003e24 V (via power module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss (typ.)\u003c\/td\u003e\n\u003ctd\u003e0.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption (Backplane)\u003c\/td\u003e\n\u003ctd\u003eMax. 10 mA at 3.3 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption (Load)\u003c\/td\u003e\n\u003ctd\u003eMax. 80 mA (no load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddress Space\u003c\/td\u003e\n\u003ctd\u003e4 bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 35 mm DIN rail is securely mounted and leveled within the enclosure.\u003c\/li\u003e\n\u003cli\u003eSnap the terminal module onto the DIN rail and slide it laterally to engage the internal backplane bus interface with the adjacent ET 200S module.\u003c\/li\u003e\n\u003cli\u003eAlign the electronic module with the terminal module guide rails and press down firmly until the locking mechanism engages.\u003c\/li\u003e\n\u003cli\u003eAlways disconnect power before inserting or removing the module to prevent electrical damage or bus errors.\u003c\/li\u003e\n\u003cli\u003eMaintain proper clearance for cooling and ensure the module is protected from high-EMI environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs this module compatible with 4-wire sensors?\u003c\/h3\u003e\u003cp\u003eNo, this specific model (6ES7134-4GB01-0AB0) is designed specifically for 2-wire transducers that draw power from the 4-20 mA current loop.\u003c\/p\u003e\u003ch3\u003eWhat does the SF LED indicate?\u003c\/h3\u003e\u003cp\u003eThe SF (Group Fault) LED indicates that a fault has occurred within the module, such as a wire break or an out-of-range signal, alerting the operator to check the specific channel status.\u003c\/p\u003e\u003ch3\u003eCan this module be used in an EOL system?\u003c\/h3\u003e\u003cp\u003eYes, we provide support and supply for this module even if it has reached its End-Of-Life status from the manufacturer, ensuring your existing infrastructure remains operational.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":44727585931352,"sku":"6ES7134-4GB01-0AB0","price":80.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_e8c4f9f5-f9ae-4590-a083-813677b60dfd.jpg?v=1788576002","url":"https:\/\/www.industriaxplc.com\/products\/6es7134-4gb01-0ab0-siemens-simatic-dp-ai-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}