{"product_id":"60m100-00-condition-monitoring-system-bently-nevada","title":"60M100-00 | Condition Monitoring System | Bently Nevada","description":"\u003ch2\u003eBently Nevada 60M100-00 Condition Monitoring System\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 60M100-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e60M100\u003c\/strong\u003e condition monitoring system, operates as a dedicated hardware component for dynamic signal acquisition and Keyphasor processing within Bently Nevada machinery protection architecture.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eNo validated suffix segmentation or functional variant mapping is defined in the provided technical dataset for 60M100-00. Any internal revision, option code, or hardware revision decoding is not specified and is therefore not expanded.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e60M100-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2 x 19 x 12.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified in source data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e18 VDC to 36 VDC input, max current 1.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e2.7 A (\u0026lt; 5 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Input Capacity\u003c\/td\u003e\n\u003ctd\u003e12 dynamic signals + 2 Keyphasor signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eADC Resolution\u003c\/td\u003e\n\u003ctd\u003e24-bit sigma-delta (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003e102.4 ksps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Range\u003c\/td\u003e\n\u003ctd\u003e110 dB @ fs = 102.4 ksps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal-to-Noise Ratio\u003c\/td\u003e\n\u003ctd\u003e110 dB @ fs = 102.4 ksps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth\u003c\/td\u003e\n\u003ctd\u003e0 to 40 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics \u0026amp; Signal Conditioning Behavior (Bently Nevada Specific Characteristics)\u003c\/h3\u003e\n\u003cp\u003eThe module processes high-frequency vibration and phase reference inputs for rotor system analysis. Dynamic acquisition channels are synchronized against Keyphasor timing inputs to support phase-resolved waveform reconstruction. Signal integrity relies on controlled impedance conditioning and rejection of cross-channel interference during high-density sampling at 102.4 ksps. The acquisition chain is designed to maintain amplitude linearity across full-scale vibration inputs within the 110 dB dynamic range window, supporting stable phase tracking under transient rotor speed variations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum number of simultaneous input channels supported by 60M100-00?\u003cbr\u003eA: The module supports up to 12 dynamic measurement channels and 2 Keyphasor reference channels simultaneously.\u003c\/p\u003e\n\u003cp\u003eQ: Is the sampling architecture synchronized between vibration and Keyphasor inputs?\u003cbr\u003eA: Yes. Keyphasor inputs are time-aligned with dynamic channels to enable phase-based signal reconstruction.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module operate across full input voltage range without reconfiguration?\u003cbr\u003eA: It accepts 18 VDC to 36 VDC input; no configuration change is defined for supply variation within this range.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe module shall be installed on a mechanically stable DIN-rail or rack-mounted backplane assembly with controlled grounding reference. Signal cabling must maintain separation between dynamic sensor inputs and power conductors to minimize induced noise. Shield termination should be performed at a single system-defined grounding point to avoid ground loop formation. Keyphasor signal routing must preserve timing integrity by minimizing cable length skew relative to vibration input channels. All connectors shall be verified for mechanical retention under continuous vibration environments prior to system energization.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44306951897176,"sku":"60M100-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/60M100-00-3.jpg?v=1782985981","url":"https:\/\/www.industriaxplc.com\/products\/60m100-00-condition-monitoring-system-bently-nevada","provider":"IndustriaX Limited","version":"1.0","type":"link"}