{"product_id":"5464-211-woodward-power-supply-module","title":"Woodward 5464-211 Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Woodward 5464-211 is a high-reliability Power Supply Module engineered for the Woodward MicroNet and NetCon control platforms. This module provides stabilized DC power to the system backplane, ensuring consistent operation of CPU and I\/O modules. Designed for mission-critical deployments in petrochemical refineries, gas turbine power plants, and maritime propulsion systems, it features advanced line regulation and surge protection. By maintaining a clean power bus and incorporating hot-swappable redundancy capabilities, the 5464-211 prevents system resets and control failures, which is essential for minimizing unscheduled downtime in continuous process industries.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigh-efficiency switching regulator for precision voltage conversion.\u003c\/li\u003e\n\u003cli\u003eIntegrated over-voltage, over-current, and thermal shutdown protection mechanisms.\u003c\/li\u003e\n\u003cli\u003eSupports load-sharing logic in redundant configurations for increased system availability.\u003c\/li\u003e\n\u003cli\u003eIntegrated diagnostic LEDs for real-time input status and output health monitoring.\u003c\/li\u003e\n\u003cli\u003eFault-monitoring circuits that relay power supply status to the main controller.\u003c\/li\u003e\n\u003cli\u003eDesigned for hot-swappable operation within MicroNet and NetCon racks.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis power supply module is specifically designed for industrial control environments where uptime is critical, including:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGas and steam turbine control systems.\u003c\/li\u003e\n\u003cli\u003ePetrochemical and refinery process automation.\u003c\/li\u003e\n\u003cli\u003eMaritime propulsion and vessel management systems.\u003c\/li\u003e\n\u003cli\u003ePower generation and distribution control platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5464-211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eSystem Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.08 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system is powered down before inserting or removing the module from the rack to prevent electrical arcing or damage to the backplane.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the designated slot and that all locking mechanisms are engaged.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate airflow around the module to ensure proper thermal dissipation within the 0-60 deg C operating range.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for all external connections to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eHandle the module using standard ESD (Electrostatic Discharge) precautions to protect sensitive internal components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 5464-211?\u003c\/h3\u003e\u003cp\u003eThe 5464-211 serves as a dedicated power supply for Woodward MicroNet and NetCon control systems, converting input power into stable, regulated DC voltages for the system backplane and associated modules.\u003c\/p\u003e\u003ch3\u003eDoes this module support redundancy?\u003c\/h3\u003e\u003cp\u003eYes, the 5464-211 is designed to support load-sharing in redundant configurations, allowing multiple modules to operate in parallel to ensure continuous power delivery.\u003c\/p\u003e\u003ch3\u003eHow do I monitor the health of the power supply?\u003c\/h3\u003e\u003cp\u003eThe module features front-panel diagnostic LEDs for immediate visual status. Additionally, internal fault-monitoring circuits communicate the module's health status directly to the main controller for centralized monitoring.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":44602660290648,"sku":"5464-211","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_c7d62a7b-28d2-45c9-868e-7d921fcf7c25.jpg?v=1786810872","url":"https:\/\/www.industriaxplc.com\/products\/5464-211-woodward-power-supply-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}