{"product_id":"330910-00-07-10-02-00-3300-nsv-proximity-probe-bently-nevada","title":"330910-00-07-10-02-00 3300 NSv Proximity Probe Bently Nevada","description":"\u003ch2\u003eBently Nevada 330910-00-07-10-02-00 3300 NSv Proximity Probe\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330910-00-07-10-02-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330910\u003c\/strong\u003e 3300 NSv Proximity Probe, operates as a dedicated hardware component for eddy-current shaft displacement measurement within Bently Nevada 3300 XL NSv Proximity Transducer Systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330910-00-07-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Proximity Probe \/ 3300 XL NSv Proximity Transducer Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e70 mm case length, M10 x 1 metric thread, 1.0 m integral cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive probe device; power supplied by matching 3300 XL NSv Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd\u003eEddy-current non-contact displacement measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Application\u003c\/td\u003e\n\u003ctd\u003eSmall shaft radial vibration and axial position monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Size Capability\u003c\/td\u003e\n\u003ctd\u003eShafts smaller than 51 mm or flat axial targets smaller than 15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Scale Factor\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) typical with matching Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Operating Range\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.5 mm (60 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 10 kHz (+0, -3 dB typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Target Material\u003c\/td\u003e\n\u003ctd\u003eAISI 4140 steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Thread\u003c\/td\u003e\n\u003ctd\u003eM10 x 1 metric thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e1.0 m integral fluid-resistant cable with miniature ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Resistance\u003c\/td\u003e\n\u003ctd\u003e4.2 +\/- 0.5 ohm DC resistance between center conductor and outer shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Mounting Torque\u003c\/td\u003e\n\u003ctd\u003e33.9 N m (300 in lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Installation Torque\u003c\/td\u003e\n\u003ctd\u003e5.1 N m (45 in lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Limit\u003c\/td\u003e\n\u003ctd\u003e100% condensing, sealed probe construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe 330910-00-07-10-02-00 uses eddy-current sensing technology to convert shaft surface displacement into proportional electrical output through a matched 3300 XL NSv Proximitor Sensor. The system provides a nominal scale factor of 7.87 V\/mm for vibration and position monitoring.\u003c\/p\u003e\n\u003cp\u003eDuring installation, technicians validate the probe gap voltage to maintain the correct operating point. The monitoring loop typically references the -10 VDC gap voltage target used by Bently Nevada proximity measurement systems. Therefore, correct probe positioning directly affects displacement accuracy and rotor dynamics analysis.\u003c\/p\u003e\n\u003cp\u003eThe probe design also supports small-target rotor applications where standard probe diameters cannot achieve required mechanical clearance. In addition, the narrow side-view configuration reduces installation restrictions around compact rotating assemblies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 330910-00-07-10-02-00 operate as a standalone sensor?\u003cbr\u003eA: No. The probe requires a compatible 3300 XL NSv Proximitor Sensor and appropriate extension cable to complete the eddy-current measurement circuit.\u003c\/p\u003e\n\u003cp\u003eQ: What target materials are used for standard calibration?\u003cbr\u003eA: The probe is calibrated for AISI 4140 steel targets. Different target materials may require calibration verification.\u003c\/p\u003e\n\u003cp\u003eQ: What installation condition affects measurement accuracy most?\u003cbr\u003eA: Probe gap setting, mounting stability, cable routing, and correct shield connection directly influence displacement signal quality.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the probe with the M10 x 1 metric threaded body according to the mechanical mounting drawing.\u003c\/li\u003e\n\u003cli\u003eSet the probe gap within the specified linear operating region before commissioning the monitoring channel.\u003c\/li\u003e\n\u003cli\u003eVerify the gap voltage at the connected Proximitor Sensor before operating the machinery.\u003c\/li\u003e\n\u003cli\u003eMaintain cable separation from high-current power conductors to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shielding according to the monitoring system grounding practice.\u003c\/li\u003e\n\u003cli\u003eAvoid excessive bending stress near the probe cable termination and ClickLoc connector area.\u003c\/li\u003e\n\u003cli\u003eConfirm the probe tip alignment with the shaft or axial target surface before final tightening.\u003c\/li\u003e\n\u003cli\u003eUse the recommended mounting torque to prevent mechanical damage while maintaining sensor\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44391171194968,"sku":"330910-00-07-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/330910-00-07-10-02-00-3.jpg?v=1784277682","url":"https:\/\/www.industriaxplc.com\/products\/330910-00-07-10-02-00-3300-nsv-proximity-probe-bently-nevada","provider":"IndustriaX Limited","version":"1.0","type":"link"}