{"product_id":"330901-00-16-05-02-cn-3300-nsv-proximity-probe-bently-nevada","title":"330901-00-16-05-02-CN 3300 NSv Proximity Probe Bently Nevada","description":"\u003ch2\u003eBently Nevada 330901-00-16-05-02-CN 3300 NSv Proximity Probe\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330901-00-16-05-02-CN\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330901\u003c\/strong\u003e 3300 NSv Proximity Probe, operates as a dedicated eddy-current measurement component for shaft displacement monitoring within the 3300 NSv Proximity Transducer System.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330901-00-16-05-02-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 UNF threaded probe, 1.6 inch overall case length, 0.5 meter integrated cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupplied by 3300 XL NSv Proximitor Sensor, -17.5 VDC to -26 VDC system supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd\u003eEddy-current non-contact displacement measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage Scale Factor\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 UNF unarmored design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e75 Ohm coaxial cable with FEP insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature gold-plated brass ClickLoc coaxial connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Thread Torque\u003c\/td\u003e\n\u003ctd\u003e7.3 N m maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Scaling and Rotor Dynamics Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe 330901 series probe provides calibrated eddy-current displacement output through the 3300 XL NSv Proximitor Sensor. The system maintains a nominal scale factor of 7.87 V\/mm, which allows the monitoring system to convert probe voltage variation into shaft position data.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the probe supports rotor dynamics analysis by measuring shaft movement without physical contact. The narrow side-view construction reduces installation interference and supports applications where standard radial probes cannot achieve required clearance.\u003c\/p\u003e\n\u003cp\u003eThe NSv system requires matched probe, extension cable, and Proximitor Sensor combinations. This configuration maintains gap voltage validation, signal linearity, and measurement accuracy during machinery operation. Proper installation normally verifies the operating gap voltage near the -10 VDC target condition.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 330901-00-16-05-02-CN probe operate with standard 3300 XL 8 mm Proximitor Sensors?\u003cbr\u003eA: No. The 330901 NSv probe requires a compatible 3300 XL NSv Proximitor Sensor and NSv extension cable configuration. Standard 3300 XL 8 mm components are not interchangeable.\u003c\/p\u003e\n\u003cp\u003eQ: What type of connector and cable assembly does this probe use?\u003cbr\u003eA: This model uses a miniature ClickLoc coaxial connector with a 0.5 meter FEP insulated coaxial cable.\u003c\/p\u003e\n\u003cp\u003eQ: How does the probe measure shaft displacement?\u003cbr\u003eA: The probe generates an eddy-current field at the probe tip. Changes in the distance between the probe and conductive shaft surface modify the electrical output signal, which the Proximitor Sensor converts into displacement data.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the probe with the correct 1\/4-28 UNF mounting hardware and maintain the specified mechanical clearance between the probe tip and the target surface.\u003c\/p\u003e\n\u003cp\u003eRoute the coaxial cable away from high-current conductors, ignition sources, and strong electromagnetic interference areas. Avoid sharp cable bends that may affect cable insulation or signal stability.\u003c\/p\u003e\n\u003cp\u003eConnect the ClickLoc connector securely and verify that the probe, extension cable, and Proximitor Sensor form a matched calibrated system.\u003c\/p\u003e\n\u003cp\u003eDuring commissioning, measure the probe gap voltage and confirm the operating condition near the required -10 VDC target range. Check signal stability while rotating equipment operates under normal conditions.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44391162675288,"sku":"330901-00-16-05-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/330901-00-16-05-02-CN-3.jpg?v=1784277576","url":"https:\/\/www.industriaxplc.com\/products\/330901-00-16-05-02-cn-3300-nsv-proximity-probe-bently-nevada","provider":"IndustriaX Limited","version":"1.0","type":"link"}