{"product_id":"330400-02-00-bently-nevada-accelerometer-acceleration-tranducer","title":"330400-02-00 | Bently Nevada | Accelerometer Acceleration Tranducer","description":"\u003ch2\u003eBently Nevada 330400-02-00 Accelerometer Acceleration Transducer\u003c\/h2\u003e\n\u003cp\u003eConfigured for vibration acceleration measurement in rotor and structural monitoring channels in TSI signal acquisition chains, the \u003cstrong\u003eBently Nevada 330400-02-00\u003c\/strong\u003e (\u003cstrong\u003e330400-02-00 Accelerometer Acceleration Transducer\u003c\/strong\u003e) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardwareSpecifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 330400-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.3 x 2.3 x 6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003ePassive sensor, N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eM8 x 1 integral stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e10.2 mV per m\/s2 (100 mV\/g) +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplitudeLinearity\u003c\/td\u003e\n\u003ctd\u003e+\/-1% up to 490 m\/s2 (50 g) peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccelerationRange\u003c\/td\u003e\n\u003ctd\u003e490 m\/s2 (50 g) peak, 10 Hz to 15 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBroadbandNoiseFloor\u003c\/td\u003e\n\u003ctd\u003e0.039 m\/s2 rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy Current Scaling and Cross-Talk Suppression in TSI Signal Chain\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada mechanical sensing architecture integrates the 330400 series output into vibration conditioning paths where signal integrity is maintained across long cable runs. In TSI acquisition environments, cross-talk suppression is enforced through controlled grounding topology and shield termination practices, reducing parasitic coupling between adjacent sensor channels.\u003c\/p\u003e\n\u003cp\u003eSignal conditioning interfaces typically align accelerometer output scaling with downstream monitoring modules. This includes validation of amplitude response consistency under high-g transient events and maintaining stable gain behavior across the defined frequency span.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the M8 x 1 integral stud suitable for high vibration mounting points?\u003cbr\u003eA: The threaded stud is designed for rigid mechanical coupling. Proper torque and full thread engagement are required to avoid resonance detachment or signal distortion.\u003c\/p\u003e\n\u003cp\u003eQ: Does the sensor require external power supply conditioning?\u003cbr\u003eA: The device operates as a passive piezoelectric acceleration transducer. External conditioning is applied only at the monitoring input stage, not at the sensor body.\u003c\/p\u003e\n\u003cp\u003eQ: How is broadband noise floor behavior handled in high-frequency environments?\u003cbr\u003eA: Noise floor performance is determined by internal element construction and cable shielding effectiveness. Proper grounding reduces induced noise components.\u003c\/p\u003e\n\u003ch3\u003eFieldInstallationGuidelines\u003c\/h3\u003e\n\u003cp\u003eInstall using full M8 x 1 thread engagement on a rigid, flat-machined surface. Avoid mounting on flexible brackets or thin sheet structures that introduce mechanical damping artifacts.\u003c\/p\u003e\n\u003cp\u003eMaintain shield continuity from sensor body to acquisition module ground reference. Avoid ground loops by ensuring single-point grounding strategy across the measurement channel.\u003c\/p\u003e\n\u003cp\u003eRoute signal cable away from high current conductors and switching devices. Maintain physical separation to minimize electromagnetic coupling into the low-level acceleration signal path.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44290869985368,"sku":"330400-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/330400-02-00-3.jpg?v=1782724631","url":"https:\/\/www.industriaxplc.com\/products\/330400-02-00-bently-nevada-accelerometer-acceleration-tranducer","provider":"IndustriaX Limited","version":"1.0","type":"link"}