{"product_id":"330104-00-05-50-11-00-bently-nevada-3300-xl-8-mm-proximity-probe","title":"330104-00-05-50-11-00 | Bently Nevada | 3300 XL 8 mm Proximity Probe","description":"\u003ch2\u003eBently Nevada 330104-00-05-50-11-00 3300 XL 8 mm Proximity Probe\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330104-00-05-50-11-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330104\u003c\/strong\u003e 3300 XL 8 mm Proximity Probe, operates as a dedicated eddy-current displacement measurement component for shaft position and vibration monitoring within Bently Nevada TSI monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330104-00-05-50-11-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEddy Current Proximity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eProbe case length: 50 mm; cable length: 5.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive probe; powered by compatible 3300 XL Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Material\u003c\/td\u003e\n\u003ctd\u003eAISI 4140 Steel calibration target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Size\u003c\/td\u003e\n\u003ctd\u003eM10 x 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Factor\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eFluidLoc FEP insulated cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eStandard configuration without agency approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Scaling and Rotor Dynamics Measurement\u003c\/h3\u003e\n\u003cp\u003eThe 330104-00-05-50-11-00 uses an eddy-current sensing principle to convert shaft displacement into a proportional electrical output through a compatible 3300 XL Proximitor Sensor. The probe maintains a 7.87 V\/mm scale factor across its 2.0 mm linear measurement range.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the system evaluates rotor dynamics parameters by measuring radial vibration, shaft position, and mechanical movement. The probe gap voltage must be validated during installation, with the typical operating target centered around the -10 VDC range when connected to the Proximitor system. Proper gap adjustment ensures correct signal scaling and displacement measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eThe probe design incorporates TipLoc molding and CableLoc construction. In addition, the FluidLoc cable structure prevents oil and process fluid migration through the cable core, maintaining signal integrity in rotating equipment environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 330104-00-05-50-11-00 probe operate without a Proximitor Sensor?\u003cbr\u003eA: No. The probe requires a compatible 3300 XL Proximitor Sensor to provide excitation and convert eddy-current impedance changes into a proportional voltage output.\u003c\/p\u003e\n\u003cp\u003eQ: What installation parameter must be checked before operation?\u003cbr\u003eA: The probe installation requires verification of mechanical gap and gap voltage. The final gap setting should match the Proximitor Sensor operating range, commonly validated near -10 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: What cable feature prevents liquid migration?\u003cbr\u003eA: The FluidLoc cable design blocks oil and process fluid movement through the internal cable structure, reducing the risk of contamination at the connection point.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the probe with the M10 x 1 threaded body fully secured against the mounting surface.\u003c\/li\u003e\n\u003cli\u003eAlign the probe tip perpendicular to the conductive target surface to maintain correct eddy-current measurement geometry.\u003c\/li\u003e\n\u003cli\u003eVerify probe gap voltage after mechanical installation and before connecting the monitoring channel to operational machinery.\u003c\/li\u003e\n\u003cli\u003eRoute the coaxial cable away from high-current power cables and strong electromagnetic interference sources.\u003c\/li\u003e\n\u003cli\u003eMaintain proper connector engagement when installing the miniature ClickLoc connector to prevent signal interruption caused by vibration.\u003c\/li\u003e\n\u003cli\u003eConnect cable shielding according to the monitoring system grounding practice to reduce electrical noise.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44467072139352,"sku":"330104-00-05-50-11-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/330104-00-05-50-11-00-3.jpg?v=1785131895","url":"https:\/\/www.industriaxplc.com\/products\/330104-00-05-50-11-00-bently-nevada-3300-xl-8-mm-proximity-probe","provider":"IndustriaX Limited","version":"1.0","type":"link"}