{"product_id":"330101-00-43-15-02-05-bently-nevada-3300-xl-8-mm-proximity-probe","title":"330101-00-43-15-02-05 | Bently Nevada 3300 XL 8 mm Proximity Probe","description":"\u003ch2\u003eBently Nevada 330101-00-43-15-02-05 3300 XL 8 mm Proximity Probe\u003c\/h2\u003e\n\u003cp\u003eConfigured for non-contacting vibration and displacement measurements in Machinery Protection Systems, the \u003cstrong\u003eBently Nevada 330101-00-43-15-02-05\u003c\/strong\u003e (\u003cstrong\u003e330101\u003c\/strong\u003e 3300 XL 8 mm Proximity Probe) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330101\u003c\/strong\u003e: 3300 XL 8 mm Probe, 3\/8-24 UNF thread, without armor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: 0.0 in minimum unthreaded length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e43\u003c\/strong\u003e: 4.3 in minimum case length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e15\u003c\/strong\u003e: 1.5 meter (4.9 feet) total length option\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e02\u003c\/strong\u003e: Miniature coaxial ClickLoc connector, standard cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e05\u003c\/strong\u003e: CSA, ATEX, IECEx agency approval option\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330101-00-43-15-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e58.5 x 1.5 x 1.5 cm (Estimated shipping size)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Configuration\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e0.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e4.3 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e1.5 meter (4.9 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eStandard cable without armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +177 degC (Typical probe rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDriven externally via Proximitor Sensor (-24 VDC system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Calibration and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe probe utilizes eddy-current technology to generate a magnetic field over the target surface. Changes in the gap distance between the probe tip and the target modify the circuit impedance. To maintain accurate scale factors (typically 7.87 V\/mm or 200 mV\/mil), gap voltage validation must be performed during installation. Setting the physical mechanical gap to achieve a baseline target of -10 VDC ensures the sensor operates within its verified linear range against a standard AISI 4140 steel target.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this probe be directly connected to a control system analog input card without a Proximitor Sensor?\u003c\/p\u003e\n\u003cp\u003eA: No. The probe behaves purely as an inductive component within an RF circuit. It requires the high-frequency conditioning provided by a matching 3300 XL Proximitor Sensor to convert impedance variations into a usable analog voltage signal.\u003c\/p\u003e\n\u003cp\u003eQ: How do cable length mismatches impact the performance of this 1.5 meter probe?\u003c\/p\u003e\n\u003cp\u003eA: The total electrical length of the probe plus the extension cable must match the tuning profile of the Proximitor Sensor (typically 5.0 meter or 9.0 meter configurations). Connecting this 1.5 meter probe to an incorrect extension cable length alters the system impedance, causing calibration errors and scaling deviations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Clearance\u003c\/strong\u003e: Maintain a minimum clearance of one probe tip diameter around the sensor tip from surrounding borehole metal to prevent side-loading interference and cross-talk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque Limits\u003c\/strong\u003e: Do not exceed standard physical torque limits when securing the 3\/8-24 UNF thread housing into the machine case to avoid casing distortion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing\u003c\/strong\u003e: Route the miniature coaxial cable through dedicated conduit or cable trays isolated from high-voltage AC lines to minimize electromagnetic noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Protection\u003c\/strong\u003e: Ensure the ClickLoc connector is clean and dry before mating. Use silicone self-coupling tape or designated connector protectors to isolate the connection from moisture and oil in the machine environment.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44269357563992,"sku":"330101-00-43-15-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/330101-00-43-15-02-05-3.jpg?v=1782199024","url":"https:\/\/www.industriaxplc.com\/products\/330101-00-43-15-02-05-bently-nevada-3300-xl-8-mm-proximity-probe","provider":"IndustriaX Limited","version":"1.0","type":"link"}