{"product_id":"3300-xl-8mm-proximity-probe-bently-nevada-330101-37-57-10-02-05","title":"3300 XL 8mm Proximity Probe | Bently Nevada 330101-37-57-10-02-05","description":"\u003ch2\u003eBently Nevada 330101-37-57-10-02-05 3300 XL 8 mm Probe\u003c\/h2\u003e\n\u003cp\u003eConfigured for eddy-current proximity measurement in the Bently Nevada 3300 XL Transducer System, the \u003cstrong\u003eBently Nevada 330101-37-57-10-02-05\u003c\/strong\u003e (\u003cstrong\u003e3300 XL 8 mm Probe\u003c\/strong\u003e) provides direct physical displacement sensing for rotating machinery shaft position monitoring.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.08 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e113 x 2 x 1.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp Range\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +177 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive device; powered via driver module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e3.7 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Case Length\u003c\/td\u003e\n\u003ctd\u003e5.7 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Cable Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m (3.3 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe probe’s linear range is factory-calibrated against its target material, with scaling factors defined in mV\/μm. Gap voltage validation targets -10 VDC when installed on standard steel shafts, ensuring correct proximity driver bias. Rotor dynamics measurements require verification of cross-talk suppression between adjacent probes to prevent signal contamination in multi-channel TSI configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the 330101-37-57-10-02-05 probe hot-swappable?\u003c\/p\u003e\n\u003cp\u003eA: No. The probe must be disconnected from the driver before removal or installation to avoid transient voltage spikes damaging the conditioning electronics.\u003c\/p\u003e\n\u003cp\u003eQ: What is the minimum bend radius for the standard cable?\u003c\/p\u003e\n\u003cp\u003eA: Maintain a minimum bend radius of 25 mm to prevent coaxial impedance changes that affect measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eQ: Does the probe require recalibration after cable replacement?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Any change in cable length or type requires full system recalibration to maintain specified linearity error limits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the probe using the supplied thread engagement of at least five full turns into the machine case. Ensure the tip is positioned within the calibrated measuring range relative to the shaft surface. Use continuous shield grounding at the driver end only to prevent ground loops. Avoid routing the probe cable parallel to high-voltage AC conductors; maintain at least 150 mm separation. Verify gap voltage with a multimeter before energizing the monitoring system.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44269409468504,"sku":"330101-37-57-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/330101-37-57-10-02-05-2.jpg?v=1782201212","url":"https:\/\/www.industriaxplc.com\/products\/3300-xl-8mm-proximity-probe-bently-nevada-330101-37-57-10-02-05","provider":"IndustriaX Limited","version":"1.0","type":"link"}