{"product_id":"285592-01-proximitor-sensor-bently-nevada","title":"285592-01 | Proximitor Sensor | Bently Nevada","description":"\u003ch2\u003eBently Nevada 285592-01 Proximitor Sensor\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 285592-01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e285592-01\u003c\/strong\u003e Proximitor Sensor, operates as a dedicated hardware component for eddy-current displacement signal conditioning within Bently Nevada 3300 XL proximity monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e285592-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 91 g to 200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified in available technical data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified; operates from -24 VDC supply input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL Series proximity monitoring system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e-24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e-18 VDC to -24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e9 m (30 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Function\u003c\/td\u003e\n\u003ctd\u003eShaft displacement and vibration monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Signal Processing and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 285592-01 Proximitor Sensor processes eddy-current probe signals by converting probe gap variation into proportional electrical output signals. The sensor performs probe scaling based on the relationship between target surface distance and gap voltage response.\u003c\/p\u003e\n\u003cp\u003eBently Nevada proximity systems use gap voltage validation methods to verify probe operating conditions. Standard commissioning procedures include checking probe bias conditions and confirming expected gap voltage values, with -10 VDC commonly used as a reference target for probe positioning verification.\u003c\/p\u003e\n\u003cp\u003eThe sensor supports rotor dynamics analysis by providing vibration and shaft position signals for machinery protection channels. Signal conditioning functions reduce measurement interference and support stable transmission of dynamic vibration data. Cross-talk suppression techniques are applied within proximity measurement systems to minimize unwanted interaction between adjacent sensing channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What measurement principle does the 285592-01 Proximitor Sensor use?\u003c\/strong\u003e\u003cbr\u003eA: The sensor uses eddy-current measurement technology to process non-contact displacement signals from compatible proximity probes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of signals does the 285592-01 provide?\u003c\/strong\u003e\u003cbr\u003eA: The device provides conditioned electrical signals representing shaft displacement and vibration information for machinery monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What power supply is required for the 285592-01?\u003c\/strong\u003e\u003cbr\u003eA: The sensor operates with a -24 VDC supply input according to the available technical specifications.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the Proximitor Sensor in a suitable monitoring cabinet location with protection from excessive vibration and contamination.\u003c\/li\u003e\n\u003cli\u003eVerify compatibility between the probe, extension cable, and Proximitor Sensor before system commissioning.\u003c\/li\u003e\n\u003cli\u003eConfirm correct -24 VDC power polarity before applying electrical power.\u003c\/li\u003e\n\u003cli\u003ePerform gap voltage verification during installation to confirm proper probe positioning.\u003c\/li\u003e\n\u003cli\u003eRoute proximity signal cables separately from high-current power cables to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eMaintain proper cable shielding and grounding practices according to industrial instrumentation installation standards.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44356912840792,"sku":"285592-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/285592-01-3.jpg?v=1783667443","url":"https:\/\/www.industriaxplc.com\/products\/285592-01-proximitor-sensor-bently-nevada","provider":"IndustriaX Limited","version":"1.0","type":"link"}