{"product_id":"140dao85300-modicon-quantum-ac-discrete-output-module-schneider-electric","title":"140DAO85300 Modicon Quantum AC Discrete Output Module Schneider Electric","description":"\u003ch2\u003eSchneider Electric 140DAO85300 Modicon Quantum AC Discrete Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for AC discrete output switching in the Modicon Quantum automation platform, the \u003cstrong\u003eSchneider Electric 140DAO85300\u003c\/strong\u003e (\u003cstrong\u003e140DAO85300\u003c\/strong\u003e AC Discrete Output Module) provides direct physical electrical execution. The \u003cstrong\u003e140DAO85300\u003c\/strong\u003e supports 32 AC output channels arranged in four groups of eight channels with an operating output range of 20 to 253 VAC and two output word addressing.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe supplied documentation identifies \u003cstrong\u003e140DAO85300\u003c\/strong\u003e as a fixed catalog number. No official suffix or ordering code decomposition is specified by the manufacturer; therefore, no suffix interpretation is provided.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e140DAO85300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum Automation Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAC Discrete Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 AC outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Groups\u003c\/td\u003e\n\u003ctd\u003e4 groups of 8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e20 to 253 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Frequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Drop\u003c\/td\u003e\n\u003ctd\u003e1.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddressing Requirement\u003c\/td\u003e\n\u003ctd\u003e2 output words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Withstand\u003c\/td\u003e\n\u003ctd\u003e400 Vrms for 1 cycle AC; 300 Vrms for 10 s AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Rating\u003c\/td\u003e\n\u003ctd\u003e4 A rms (20 to 132 VAC) per output; 3 A rms (170 to 253 VAC) per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Current Limit\u003c\/td\u003e\n\u003ctd\u003e16 A rms per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Current\u003c\/td\u003e\n\u003ctd\u003e15 A for 2 cycles; 12 A for 1 cycle; 8 A for 3 cycles per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Leakage\u003c\/td\u003e\n\u003ctd\u003e1 mA rms at 24 VAC; 1 mA rms at 48 VAC; 2 mA rms at 115 VAC; 2.5 mA rms at 230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 0.5 ms ON to OFF; \u0026lt;= 0.5 ms OFF to ON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eInternal RC filter; internal 4 A fuse per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edV\/dt\u003c\/td\u003e\n\u003ctd\u003e400 V\/ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Current Requirement\u003c\/td\u003e\n\u003ctd\u003e320 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePower dissipation = 1.60 + (1.0 V x total module load current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Indicators\u003c\/td\u003e\n\u003ctd\u003e32 green output LEDs, 1 green Active LED, 1 red Fault LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003eUp to 5000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, cUL, FM Class 1 Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No. 142, UL 508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Immunity\u003c\/td\u003e\n\u003ctd\u003e8 kV air ESD, 4 kV contact ESD, 10 V\/m RF immunity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication and I\/O Density Characteristics\u003c\/h3\u003e\n\u003cp\u003eWithin the Modicon Quantum platform, the module exchanges output image data through the system backplane using two output words. The 32-channel density enables centralized AC load switching while maintaining grouped output organization. The module requires 320 mA from the backplane and provides local LED diagnostics for channel status, communication status, and external fault indication.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module support hot replacement while the rack is energized?\u003c\/strong\u003e\u003cbr\u003eA: The supplied documentation does not specify hot-swap capability. Installation and replacement should follow the controller and rack maintenance procedures defined for the Modicon Quantum platform.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many output data words are required by the PLC configuration?\u003c\/strong\u003e\u003cbr\u003eA: The module requires two output words for addressing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What output protection is integrated into the hardware?\u003c\/strong\u003e\u003cbr\u003eA: Each output includes an internal RC filter for transient suppression and internal 4 A fuse protection.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the AC load voltage is within the specified 20 to 253 VAC operating range before energizing the module.\u003c\/li\u003e\n\u003cli\u003eObserve the module current limit and individual channel loading limits when distributing field loads.\u003c\/li\u003e\n\u003cli\u003eSeparate AC output wiring from low-level analog and communication cables to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eTighten field terminal connections according to the applicable installation manual and inspect periodically for loose conductors.\u003c\/li\u003e\n\u003cli\u003eEnsure protective earth grounding of the control cabinet complies with local electrical standards before commissioning.\u003c\/li\u003e\n\u003cli\u003eConfirm module LED indications after startup to verify communication status and output operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44290456813656,"sku":"140DAO85300","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/140DAO85300-3.jpg?v=1782716705","url":"https:\/\/www.industriaxplc.com\/products\/140dao85300-modicon-quantum-ac-discrete-output-module-schneider-electric","provider":"IndustriaX Limited","version":"1.0","type":"link"}