{"product_id":"07kt98-gjr5253100r0160-abb-plc-basic-units","title":"07KT98 GJR5253100R0160 ABB PLC Basic Units","description":"\u003ch2\u003eABB 07KT98 Basic Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for PLC processing, onboard I\/O execution, and CS31\/ARCNET communication, the \u003cstrong\u003eABB 07KT98 GJR5253100R0160\u003c\/strong\u003e (\u003cstrong\u003e07KT98\u003c\/strong\u003e Basic Unit) provides direct control and data-processing functions within the Advant Controller 31 (AC31) system.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e07KT98 GJR5253100R0160\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eBasic Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAdvant Controller 31 (AC31)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Program Memory\u003c\/td\u003e\n\u003ctd\u003e240 kB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Data Memory\u003c\/td\u003e\n\u003ctd\u003e120 kB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash EPROM\u003c\/td\u003e\n\u003ctd\u003e512 kB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM\u003c\/td\u003e\n\u003ctd\u003e2 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBinary Flags\u003c\/td\u003e\n\u003ctd\u003e8192\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWord Flags\u003c\/td\u003e\n\u003ctd\u003e8192\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-Word Flags\u003c\/td\u003e\n\u003ctd\u003e1024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e24 channels, 3 groups of 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e16 transistor outputs, 2 groups of 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Output Current\u003c\/td\u003e\n\u003ctd\u003e500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigurable Digital I\/O\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Ranges\u003c\/td\u003e\n\u003ctd\u003e0-10 V, +\/-10 V, 0-20 mA, Pt100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Ranges\u003c\/td\u003e\n\u003ctd\u003e+\/-10 V, 0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interfaces\u003c\/td\u003e\n\u003ctd\u003e2 x EIA RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCS31 Interface\u003c\/td\u003e\n\u003ctd\u003eEIA RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 31 remote I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARCNET Interface\u003c\/td\u003e\n\u003ctd\u003eIntegrated, BNC connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Speed Counter\u003c\/td\u003e\n\u003ctd\u003e7 operating modes, up to 50 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Storage\u003c\/td\u003e\n\u003ctd\u003eSmartMedia card slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 0.35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e240 mm x 140 mm x 85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 8.4 W at 24 VDC and 0.35 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Processing and Industrial Network Functions\u003c\/h3\u003e\n\u003cp\u003eThe 07KT98 executes PLC control logic while managing onboard digital and analog signals. It supports two EIA RS-232 ports for programming and debugging, while the CS31 EIA RS-485 interface connects distributed I\/O devices. In addition, the integrated ARCNET interface supports peer-to-peer controller communication.\u003c\/p\u003e\n\u003cp\u003eThe configurable I\/O channels allow the unit to handle mixed signal requirements. Analog inputs accept voltage, current, and Pt100 sensor signals, while analog outputs provide voltage or current signals. Furthermore, the integrated high-speed counter supports frequencies up to 50 kHz across seven operating modes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 07KT98 operate without remote I\/O modules?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The supplied specifications identify the unit as capable of standalone PLC operation with integrated onboard I\/O.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which communication interfaces are integrated into the 07KT98?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The unit provides two EIA RS-232 ports, one EIA RS-485 CS31 system bus interface, and an ARCNET interface through a BNC connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What signal types can the analog channels process?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The eight analog inputs support 0-10 V, +\/-10 V, 0-20 mA, and Pt100 configurations. The four analog outputs support +\/-10 V, 0-20 mA, and 4-20 mA.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the unit securely on the designated controller installation structure and maintain access to all connectors.\u003c\/li\u003e\n\u003cli\u003eRoute RS-232, CS31, ARCNET, digital, and analog signal cables separately where practical to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eUse appropriate shielded cabling for communication and low-level analog signals.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shields according to the AC31 installation design and site grounding practice.\u003c\/li\u003e\n\u003cli\u003eVerify the 24 VDC supply polarity and voltage before energizing the unit.\u003c\/li\u003e\n\u003cli\u003eCheck the maximum output loading before connecting field devices to transistor outputs.\u003c\/li\u003e\n\u003cli\u003eKeep analog signal wiring away from high-current switching conductors and motor cables.\u003c\/li\u003e\n\u003cli\u003eInspect the BNC connection and CS31 wiring for secure mechanical engagement before commissioning.\u003c\/li\u003e\n\u003cli\u003eBack up application programs and configuration data using the supported SmartMedia card function where required.\u003c\/li\u003e\n\u003cli\u003eConfirm I\/O addressing and signal configuration before placing the PLC into automatic operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44685609205848,"sku":"07KT98 GJR5253100R0160","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/07KT98-GJR5253100R0160-3_1200x1200_15df0ca9-3112-4b67-933a-76417adaa66f.jpg?v=1788158249","url":"https:\/\/www.industriaxplc.com\/products\/07kt98-gjr5253100r0160-abb-plc-basic-units","provider":"IndustriaX Limited","version":"1.0","type":"link"}