{"product_id":"yokogawa-nfdv551-p60-digital-output-module","title":"Yokogawa NFDV551-P60 Digital Output Module","description":"\u003ch2\u003eYokogawa NFDV551-P60 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa NFDV551-P60\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNFDV551\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for discrete signal switching across STARDOM\/FIO subsystem platforms. It provides isolated current-sink outputs for direct electrical execution of field devices such as solenoid valves, relays, and indicator lamps.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\/Brand\u003c\/td\u003e\n\u003ctd\u003eNFDV551-P60 \/ Yokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Applied Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Power Supply Voltage Range\u003c\/td\u003e\n\u003ctd\u003e20.4 to 26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Voltage \/ Current\u003c\/td\u003e\n\u003ctd\u003e24 V DC, 50 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e100 mA per channel at 26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput ON Voltage (Max)\u003c\/td\u003e\n\u003ctd\u003e2 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current (OFF)\u003c\/td\u003e\n\u003ctd\u003e0.1 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Format\u003c\/td\u003e\n\u003ctd\u003eCurrent sink (open collector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e≤ 3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e700 mA @ 5 V DC (system), 60 mA @ 24 V DC (field)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 90 × 60 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +80 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal or MIL connector cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Control\/DCS Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eChannel-to-channel isolation ensures electrical separation between outputs, minimizing cross-talk in dense I\/O arrays.\u003c\/li\u003e\n\u003cli\u003eCompatible with 4-20 mA HART loop monitoring and can interface with FOUNDATION Fieldbus or Profibus PA via STARDOM\/FIO controllers.\u003c\/li\u003e\n\u003cli\u003eCold junction compensation (CJc) supported for accurate diagnostics when used with temperature-sensitive output devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eQ: Can the module be hot-swapped?\u003cbr\u003eA: The NFDV551-P60 is not designed for live backplane insertion. Ensure the system power is off before replacing modules.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum load per channel?\u003cbr\u003eA: Each channel supports up to 100 mA at 26.4 V DC; exceeding this may damage the module.\u003c\/p\u003e\n\u003cp\u003eQ: How is output fallback handled?\u003cbr\u003eA: The module supports HOLD (retain last state), OFF (force outputs off), or NO (no action) configurations during communication loss.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField Installation Guidelines\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMount modules securely in a STARDOM\/FIO-compatible rack with appropriate clearance for heat dissipation.\u003c\/li\u003e\n\u003cli\u003eEnsure field wiring is routed to avoid EMI interference; shielded twisted pair is recommended for long runs.\u003c\/li\u003e\n\u003cli\u003eConnect the system and field power supplies according to polarity markings; confirm voltage ranges.\u003c\/li\u003e\n\u003cli\u003eVerify that all common lines are correctly grouped to maintain proper isolation.\u003c\/li\u003e\n\u003cli\u003eDo not exceed terminal torque specifications; over-tightening can damage pressure clamp terminals.\u003c\/li\u003e\n\u003cli\u003eUse MIL connectors only if cable routing requires flexible connection; maintain proper grounding to prevent signal leakage.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44165729288280,"sku":"NFDV551-P60","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/NFDV551-P60-2.jpg?v=1780368813","url":"https:\/\/www.industriaxplc.com\/id\/products\/yokogawa-nfdv551-p60-digital-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}