{"product_id":"yokogawa-f3da04-6r-analog-output-module","title":"Yokogawa F3DA04-6R Analog Output Module","description":"\u003ch2\u003eYokogawa F3DA04-6R Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for digital-to-analog signal conversion in FA-M3 controller output processing, the \u003cstrong\u003eYokogawa F3DA04-6R\u003c\/strong\u003e (\u003cstrong\u003eF3DA04\u003c\/strong\u003e) Analog Output Module provides direct electrical execution of 4-channel isolated analog signal generation for voltage and current loop interfaces within FA-M3 backplane systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u0026amp;Model Matrix\u003c\/h3\u003e\n\u003cp\u003eNo documented mechanical or functional suffix segmentation beyond full model designation F3DA04-6R is provided in the source specification. The “-6R” identifier is treated as an ordering variant without disclosed functional partitioning.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa F3DA04-6R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 190 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC: 360 mA (internal), 24 VDC: approx. 120 mA (external supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e4 isolated analog output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Types\u003c\/td\u003e\n\u003ctd\u003eVoltage: -10 to +10 VDC, 0 to 10 VDC, 1 to 5 VDC; Current: 4 to 20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit signed data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Speed\u003c\/td\u003e\n\u003ctd\u003e100 us per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel isolation via photocoupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstand Voltage\u003c\/td\u003e\n\u003ctd\u003e500 VAC for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Interface\u003c\/td\u003e\n\u003ctd\u003e18-point detachable terminal block (M3 screw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Output Channel Isolation Architecture\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa F3DA04-6R\u003c\/strong\u003e implements channel-to-channel and channel-to-backplane isolation using photocoupler-based separation stages. Within FA-M3 system architecture, analog output generation is decoupled from CPU logic domain, preventing ground potential propagation across field wiring loops. This design aligns with process control loop segmentation requirements for mixed voltage\/current output configurations, including 4-20 mA loop-driven actuator interfaces.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can output channels be configured independently for voltage and current modes?\u003cbr\u003eA: Yes. Each channel supports software-defined selection between voltage and current output ranges without hardware jumper configuration.\u003c\/p\u003e\n\u003cp\u003eQ: What is the behavior during CPU stop condition?\u003cbr\u003eA: The module supports output hold or preset fallback behavior depending on system configuration, maintaining last valid or predefined analog values.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swap operation supported on the terminal block?\u003cbr\u003eA: Terminal block is mechanically detachable; however, field wiring removal under energized conditions is not specified as supported.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eShielded twisted-pair cabling shall be used for all analog output wiring to reduce electromagnetic coupling into 4-20 mA and voltage loops. Shield termination shall be referenced to frame ground (FG) at a single point to prevent ground loop formation. External 24 VDC supply must be applied to designated power terminals prior to analog loop activation. Terminal torque for M3 screws shall follow standard industrial control cabinet practices to ensure stable contact impedance. Channel wiring separation is required when routing mixed current and voltage outputs to minimize cross-coupling.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44176172220504,"sku":"F3DA04-6R","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/F3DA04-6R.jpg?v=1780457101","url":"https:\/\/www.industriaxplc.com\/id\/products\/yokogawa-f3da04-6r-analog-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}