{"product_id":"yokogawa-f3cu04-1s-temperature-pid-control-module","title":"Yokogawa F3CU04-1S Temperature PID Control Module","description":"\u003ch2\u003eYokogawa F3CU04-1S Temperature PID Control Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa F3CU04-1S\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eF3CU04-1S\u003c\/strong\u003e Temperature PID Control Module, operates as a dedicated hardware component for multi-loop temperature regulation within FA-M3 Range-Free Multi-Controller systems. It provides direct execution of continuous and time-proportional PID outputs for simultaneous heating and cooling control across four independent loops.\u003c\/p\u003e\n\u003ch3\u003eHardwareSpecifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa F3CU04-1S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e300 g approx.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eDouble-slot module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 degC to 55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorageTemp\u003c\/td\u003e\n\u003ctd\u003e-20 degC to 75 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingHumidity\u003c\/td\u003e\n\u003ctd\u003e10% to 90% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e470 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Control Loops\u003c\/td\u003e\n\u003ctd\u003e4 loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eThermocouples, RTDs, DC voltage per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Period\u003c\/td\u003e\n\u003ctd\u003e200 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Output Types\u003c\/td\u003e\n\u003ctd\u003eTime-proportional PID (Open Collector), Continuous PID 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Outputs\u003c\/td\u003e\n\u003ctd\u003e4 per loop with ON-delay function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003eTwo 18-point terminal blocks with M3.5 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarm-up Time\u003c\/td\u003e\n\u003ctd\u003e30 minutes min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Ambient Temp Change Rate\u003c\/td\u003e\n\u003ctd\u003e10 degC\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Control Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module supports isolated input channels for precise loop-to-loop regulation and cold junction compensation (CJc) for thermocouple inputs. Continuous 4-20 mA outputs integrate directly with analog actuators, while embedded dynamic auto-tuning recalculates PID constants based on setpoint changes. Channel-to-channel isolation reduces electrical interference between loops.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eQ: VnA: Can the F3CU04-1S be hot-swapped without system interruption?\u003cbr\u003eA: No, this module requires power-down prior to insertion or removal to maintain loop integrity.\u003c\/p\u003e\n\u003cp\u003eQ: VnA: Are the PID parameters retained after power loss?\u003cbr\u003eA: Yes, all setpoints and PID constants are stored in internal non-volatile EEPROM.\u003c\/p\u003e\n\u003cp\u003eQ: VnA: What is the maximum backplane current draw per module?\u003cbr\u003eA: The module consumes 470 mA at 5 VDC, and backplane ratings should account for cumulative loop modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField Installation Guidelines\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module in a vertical orientation on the FA-M3 base plate.\u003c\/li\u003e\n\u003cli\u003eConnect external devices to the 18-point terminal blocks using M3.5 screws; torque to recommended industrial standards.\u003c\/li\u003e\n\u003cli\u003eMaintain at least 20 mm spacing between modules to prevent thermal buildup.\u003c\/li\u003e\n\u003cli\u003eEnsure signal cables are shielded and grounded at one end to minimize electrical noise.\u003c\/li\u003e\n\u003cli\u003eAvoid routing high-voltage AC lines parallel to thermocouple or RTD wiring to prevent cross-talk.\u003c\/li\u003e\n\u003cli\u003eAllow a minimum warm-up of 30 minutes before critical loop tuning operations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44176131686488,"sku":"F3CU04-1S","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/F3CU04-1S.jpg?v=1780456921","url":"https:\/\/www.industriaxplc.com\/id\/products\/yokogawa-f3cu04-1s-temperature-pid-control-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}