{"product_id":"terminal-block-module-te32-yokogawa","title":"Terminal Block Module | TE32 | Yokogawa","description":"\u003ch2\u003eYokogawa TE32 Terminal Block Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa TE32\u003c\/strong\u003e terminal block module, also cataloged as the \u003cstrong\u003eTE32\u003c\/strong\u003e general-purpose terminal board, operates as a dedicated hardware component for high-density field signal interfacing within CENTUM CS3000, CENTUM VP, and ProSafe-RS systems.\u003c\/p\u003e\n\u003cp\u003eHardware Specifications\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\/Brand\u003c\/td\u003e\n\u003ctd\u003eTE32 \/ Yokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Contact Points\u003c\/td\u003e\n\u003ctd\u003e32 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eM4 Screw-clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Pitch\u003c\/td\u003e\n\u003ctd\u003e5.08 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcceptable Wire Size\u003c\/td\u003e\n\u003ctd\u003e0.2 to 2.5 mm2 (AWG 24 to 12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e300 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current\u003c\/td\u003e\n\u003ctd\u003e6 A per terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e≥100 MΩ at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC \/ 1,500 V AC for 1 min (depending on module pairing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eFlame-retardant polyamide (UL 94 V-0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Weight\u003c\/td\u003e\n\u003ctd\u003e0.36 kg (module) \/ 3.0 kg (shipping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 50 degC (some variants –20 to 70 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e–40 to 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 90% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe TE32 module supports channel-to-channel electrical isolation, ensuring signal integrity across adjacent DI\/DO and AI\/AO circuits. It is compatible with 4-20 mA HART loop protocol and can integrate with FOUNDATION Fieldbus or Profibus PA networks. Cold-junction compensation (CJc) in analog inputs is supported when paired with compatible AI modules, maintaining precise measurement under variable temperature conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the TE32 support hot-swap installation in DCS cabinets?\u003cbr\u003eA: The TE32 does not support hot-swap; all connections must be de-energized prior to installation or maintenance.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum current load per terminal under continuous operation?\u003cbr\u003eA: The rated continuous current is 6 A per terminal. Exceeding this may degrade terminal clamp reliability and insulation.\u003c\/p\u003e\n\u003cp\u003eQ: Is firmware or software required for TE32 operation?\u003cbr\u003eA: The TE32 is a passive terminal block; no firmware or configuration software is required. Electrical connectivity is handled entirely through field wiring to I\/O modules.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the TE32 on DIN rails or according to Yokogawa panel layout specifications.\u003c\/li\u003e\n\u003cli\u003eEnsure proper torque on M4 screw terminals to maintain secure electrical contact without damaging conductors.\u003c\/li\u003e\n\u003cli\u003eRoute field wiring to minimize cross-talk; maintain separation between analog and digital signals where possible.\u003c\/li\u003e\n\u003cli\u003eGround the module housing according to local electrical codes to prevent transient surges.\u003c\/li\u003e\n\u003cli\u003eAvoid bending wires excessively at the terminal interface; maintain the minimum bend radius recommended for the wire gauge.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44219582840920,"sku":"TE32","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TE32.jpg?v=1781146348","url":"https:\/\/www.industriaxplc.com\/id\/products\/terminal-block-module-te32-yokogawa","provider":"IndustriaX Limited","version":"1.0","type":"link"}