{"product_id":"tc-hai081-high-level-analog-input-module-honeywell","title":"TC-HAI081 | High-Level Analog Input Module | Honeywell","description":"\u003ch2\u003eHoneywell TC-HAI081 High-Level Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell TC-HAI081 (9060029-04)\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTC-HAI081\u003c\/strong\u003e High-Level Analog Input Module, operates as a dedicated hardware component for converting field analog signals into digital process values within Honeywell Series C I\/O systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-HAI081\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e9060029-04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Level Analog Input Module with HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS \/ PlantCruise Series C I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA \/ 1-5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Conversion\u003c\/td\u003e\n\u003ctd\u003e16-bit ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003eHART pass-through communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-system galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Power Input\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 3.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eSeries C I\/O rack installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap Capability\u003c\/td\u003e\n\u003ctd\u003eSupported for removal and insertion under power (RIUP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop and Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe TC-HAI081 processes standard 4-20 mA analog transmitter signals and supports HART loop communication for smart field device access. The module separates analog measurement processing from digital HART data transmission, allowing configuration and diagnostic information to pass through the I\/O architecture.\u003c\/p\u003e\n\u003cp\u003eThe input circuit provides channel-to-system isolation to reduce signal interference between field wiring and controller electronics. The 16-bit analog-to-digital converter converts measured process variables into digital values for execution by the Honeywell controller environment.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the TC-HAI081 support direct HART communication with field transmitters?\u003cbr\u003eA: Yes. The module provides HART pass-through capability, allowing digital communication with compatible smart transmitters while maintaining the 4-20 mA measurement loop.\u003c\/p\u003e\n\u003cp\u003eQ: Can the TC-HAI081 be replaced while the I\/O rack remains powered?\u003cbr\u003eA: Yes. The module supports removal and insertion under power (RIUP) when installed in a compatible Series C I\/O system configuration.\u003c\/p\u003e\n\u003cp\u003eQ: What type of field signals can be connected to the TC-HAI081?\u003cbr\u003eA: The module accepts standard high-level analog inputs including 4-20 mA current signals and 1-5 VDC voltage signals from field instrumentation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in the designated Honeywell Series C I\/O rack position according to the system hardware configuration.\u003c\/li\u003e\n\u003cli\u003eSeparate analog field wiring from high-voltage power cables to minimize electrical noise coupling.\u003c\/li\u003e\n\u003cli\u003eUse shielded instrumentation cable for analog signal connections where required by the installation design.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the plant grounding specification and avoid multiple grounding points on signal shields.\u003c\/li\u003e\n\u003cli\u003eVerify transmitter loop polarity and signal range before applying field power.\u003c\/li\u003e\n\u003cli\u003eConfirm controller configuration matches the installed module type and channel assignments before process operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44357113806936,"sku":"TC-HAI081 9060029-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TC-HAI0819060029-04-2.jpg?v=1783670911","url":"https:\/\/www.industriaxplc.com\/id\/products\/tc-hai081-high-level-analog-input-module-honeywell","provider":"IndustriaX Limited","version":"1.0","type":"link"}