{"product_id":"schneider-tsxamz600-analogue-module","title":"Schneider TSXAMZ600 Analogue Input\/Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Schneider TSXAMZ600 is a high-performance analogue I\/O module designed for integration within industrial automation systems. This module provides precise signal acquisition and control capabilities, featuring four analogue inputs and two analogue outputs. It is specifically engineered for compatibility with the RMS-TSG-TZ-C series PLC architecture, offering a reliable solution for modular process control and monitoring applications.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFour configurable analogue input channels supporting voltage (0-10 V) or current (0-20 mA) signals.\u003c\/li\u003e\n\u003cli\u003eTwo analogue output channels for precise control of actuators and process instrumentation.\u003c\/li\u003e\n\u003cli\u003eHigh-resolution 12-bit conversion for accurate data processing.\u003c\/li\u003e\n\u003cli\u003eCompact, space-saving design suitable for standard PLC rack mounting.\u003c\/li\u003e\n\u003cli\u003eRobust construction designed for industrial environments with an operating temperature range of 0 degC to 60 degC.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is suitable for various industrial automation tasks, including process variable monitoring, actuator control, and integration into complex PLC-based control loops within manufacturing and process industries.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXAMZ600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eRMS-TSG-TZ-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue Inputs\u003c\/td\u003e\n\u003ctd\u003e4 channels (0-10 V \/ 0-20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue Outputs\u003c\/td\u003e\n\u003ctd\u003e2 channels (0-10 V \/ 0-20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 kOhm (voltage), 250 Ohm (current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Load Capacity\u003c\/td\u003e\n\u003ctd\u003e500 Ohm maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e10 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC rack power is disconnected before installing or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eMount the module securely in the designated rack slot, ensuring proper alignment with the backplane connector.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for all analogue signal connections to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices for the PLC system to ensure signal integrity and safety.\u003c\/li\u003e\n\u003cli\u003eKeep the module away from high-voltage power lines and high-EMI equipment to prevent signal noise.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation within the control cabinet to maintain operating temperatures within the specified 0-60 degC range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the resolution of the TSXAMZ600 module?\u003c\/strong\u003e\u003cbr\u003eThe module features 12-bit resolution for both input and output channels.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this module handle both voltage and current signals?\u003c\/strong\u003e\u003cbr\u003eYes, the module is designed to support both 0-10 V voltage and 0-20 mA current signals for its input and output channels.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the required power supply for this module?\u003c\/strong\u003e\u003cbr\u003eThe TSXAMZ600 operates on a 24 VDC power supply.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":44621310820440,"sku":"TSXAMZ600","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_8f169ba3-8abe-43d8-b835-a16cd7469230.jpg?v=1787071369","url":"https:\/\/www.industriaxplc.com\/id\/products\/schneider-tsxamz600-analogue-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}