{"product_id":"schneider-modicon-tsx-micro-tsxdsz08r5-digital-output-modules","title":"Schneider Electric TSXDSZ08R5 Modicon TSX Micro Digital Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\u003cp\u003eThe Schneider Electric TSXDSZ08R5 is a specialized relay output module designed for integration within the Modicon TSX Micro programmable logic controller architecture. This unit provides 8 discrete, normally open (NO) relay outputs, enabling the control of high-load field devices directly from the PLC backplane. It is engineered for industrial environments where galvanic isolation and the ability to switch varying voltage levels are critical for maintaining system integrity and protecting sensitive processor circuitry.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEight independent, normally open (NO) mechanical relay outputs.\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between the internal logic bus and field-side contacts for enhanced safety.\u003c\/li\u003e\n\u003cli\u003eIntegrated RC snubber circuits to suppress voltage spikes during reactive load switching.\u003c\/li\u003e\n\u003cli\u003eLED status indicators for each channel to verify output state and facilitate rapid field diagnostics.\u003c\/li\u003e\n\u003cli\u003eDesigned for operation across a broad range of AC and DC voltage applications.\u003c\/li\u003e\n\u003cli\u003eRemovable screw terminal block for efficient wiring and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is suitable for various industrial automation tasks, including motor starter control, solenoid valve actuation, and interposing logic for high-voltage circuits. It is commonly deployed in sectors such as automated manufacturing, water treatment, and HVAC control systems where reliable, isolated discrete switching is required.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXDSZ08R5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e8 Normally Open (NO) Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24-240 VAC \/ 24-48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current per Channel\u003c\/td\u003e\n\u003ctd\u003e2.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Module Current Limit\u003c\/td\u003e\n\u003ctd\u003e10.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Switching Current\u003c\/td\u003e\n\u003ctd\u003e1 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Power Consumption\u003c\/td\u003e\n\u003ctd\u003e45 mA at 5 VDC \/ 60 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Voltage\u003c\/td\u003e\n\u003ctd\u003e2000 VAC (Contacts to Bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e10 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC rack is powered down before installing or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eMount the module securely into the designated TSX Micro rack slot, ensuring proper alignment with the backplane connector.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for field wiring to minimize electromagnetic interference (EMI) in high-noise industrial environments.\u003c\/li\u003e\n\u003cli\u003eVerify that the total load current across all channels does not exceed the 10 A module limit.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation within the control cabinet to keep ambient temperatures within the specified 0 to 60 deg C range.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD precautions to prevent damage to internal PCB components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eIs the TSXDSZ08R5 compatible with all TSX Micro racks?\u003c\/strong\u003e\u003cbr\u003eYes, this module is specifically designed for the Modicon TSX Micro series. Please ensure your specific base configuration supports the slot requirements for this module type.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes this module provide protection against inductive surges?\u003c\/strong\u003e\u003cbr\u003eYes, the module includes an onboard RC snubber array to mitigate counter-electromotive force spikes caused by inductive loads like relay coils or solenoids.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I replace the terminal block if it becomes damaged?\u003c\/strong\u003e\u003cbr\u003eThe TSXDSZ08R5 utilizes a removable screw terminal block, which allows for field replacement or pre-wiring without disturbing the module's connection to the backplane.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":44744926036056,"sku":"TSXDSZ08R5","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_30e57339-2a9f-4c89-8e1c-0c78ebd0cf65.jpg?v=1788930804","url":"https:\/\/www.industriaxplc.com\/id\/products\/schneider-modicon-tsx-micro-tsxdsz08r5-digital-output-modules","provider":"IndustriaX Limited","version":"1.0","type":"link"}