{"product_id":"schneider-electric-tsxpsy2600m-power-supply-module","title":"Schneider Electric TSXPSY2600M Power Supply Module","description":"\u003ch1\u003eSchneider Electric TSXPSY2600M Power Supply Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for regulated AC-to-DC power conversion in Modicon backplane architectures, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric TSXPSY2600M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eTSXPSY2600M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower supply module) provides direct physical\/electrical execution for supplying 5 VDC and 24 VDC rails within Modicon Premium rack-based systems.\u003c\/p\u003e\n\u003ch3\u003eHardwareSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric TSXPSY2600M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e100..240 V AC input, 300 mA @ 240 V \/ 500 mA @ 100 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz (47..63 Hz limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e37 A @ 100 V, 75 A @ 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Outputs\u003c\/td\u003e\n\u003ctd\u003e5 V DC (5 A), 24 V DC auxiliary outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Useful Power\u003c\/td\u003e\n\u003ctd\u003e26 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eFuse 4 A (5 x 20 mm), overload, short-circuit, overvoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eBackplane Power Distribution and Firmware Compatibility Layer\u003c\/h2\u003e\n\u003cp\u003eThe TSXPSY2600M interfaces with Modicon Premium backplane architecture, delivering regulated DC rails to distributed I\/O and CPU modules via internal bus coupling. Backplane communication is synchronized through deterministic rack-level timing, ensuring stable module enumeration and power sequencing during system initialization.\u003c\/p\u003e\n\u003cp\u003eFirmware and module recognition sequences rely on consistent voltage stabilization across the 5 V DC rail, enabling predictable bootstrapping of PLC CPU and I\/O modules. Backplane load distribution must remain within rated 5 V DC current limits to prevent bus instability or module reset events under dynamic I\/O density scaling conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the TSXPSY2600M be hot-swapped under load?\u003c\/strong\u003e\u003cbr\u003eA: The module is not designed for live hot-swapping. Removal under energized backplane conditions may cause voltage collapse across 5 V DC rails and reset connected CPU\/I\/O modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the limitation of the 5 V DC backplane supply?\u003c\/strong\u003e\u003cbr\u003eA: The 5 V DC output is limited to 5 A total. Exceeding this load can trigger internal protection shutdown or unstable backplane signaling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module support redundancy operation?\u003c\/strong\u003e\u003cbr\u003eA: Redundant configuration is not inherent to the TSXPSY2600M. System-level redundancy depends on external architecture design within the Modicon Premium platform.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFieldInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure AC input is isolated before installation. Mount the module securely within the designated Modicon Premium rack slot to maintain backplane alignment integrity. Verify correct seating of the connector to prevent partial contact on the DC bus pins.\u003c\/p\u003e\n\u003cp\u003eMaintain proper segregation between AC input wiring and low-voltage DC backplane lines. Shielded grounding practices should follow rack grounding terminals to minimize conducted noise across the power distribution path. Do not exceed rated current draw on either 5 V DC or 24 V DC outputs during commissioning.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44246665003096,"sku":"TSXPSY2600M","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TSXPSY2600M-3.jpg?v=1781603929","url":"https:\/\/www.industriaxplc.com\/id\/products\/schneider-electric-tsxpsy2600m-power-supply-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}