{"product_id":"schneider-electric-bmxddi1602h-modicon-x80-discrete-input-module","title":"Schneider Electric BMXDDI1602H Modicon X80 Discrete Input Module","description":"\u003ch2\u003eSchneider Electric BMXDDI1602H Modicon X80 Discrete Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete signal acquisition in Modicon X80 backplane I\/O systems, the \u003cstrong\u003eSchneider Electric BMXDDI1602H\u003c\/strong\u003e (\u003cstrong\u003eBMXDDI1602H Discrete Input Module\u003c\/strong\u003e) provides direct physical\/electrical execution within Schneider Electric Modicon X80 architectures. The module implements 16-channel 24 V DC current sink (positive logic) input acquisition with isolated channel structure for field signal interfacing.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eNo explicit manufacturer-defined suffix segmentation for BMXDDI1602H is provided in the supplied technical dataset. Model interpretation is limited to catalog identifier level only.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric BMXDDI1602H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.115 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003eNot specified (sensor supply referenced up to 60 degC \/ 70 degC conditions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 discrete inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eIsolated current sink (logic positive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e3.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e4 ms typical \/ 7 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Compatibility\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-5-2, IEC 61131-2 Type 3 proximity sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Consumption\u003c\/td\u003e\n\u003ctd\u003e76 mA at 3.3 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Deterministic I\/O Handling and Firmware Integration\u003c\/h3\u003e\n\u003cp\u003eWithin Modicon X80 systems, the BMXDDI1602H integrates into the backplane communication layer through deterministic I\/O refresh cycles synchronized with PLC scan execution. Channel state acquisition is executed through fixed-latency sampling windows (4 ms typical), enabling predictable input mapping to process image tables.\u003c\/p\u003e\n\u003cp\u003eFirmware compatibility is aligned with Schneider Electric X80 platform I\/O modules, supporting consistent module identification and hot module detection at rack level without requiring reconfiguration of I\/O addressing tables.\u003c\/p\u003e\n\u003cp\u003eSignal conditioning is internally optimized for 24 V DC current sink topology, ensuring stable logic interpretation under standard IEC 61131-2 Type 3 sensor electrical behavior.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support hot-swap insertion on an energized backplane?\u003cbr\u003eA: The module is designed for rack-based X80 installation. Hot insertion behavior depends on system backplane configuration and PLC rack power management rules.\u003c\/p\u003e\n\u003cp\u003eQ: What is the effect of backplane load on input scan timing?\u003cbr\u003eA: Input scan timing is determined by PLC task cycle and backplane update mechanism; the module itself maintains fixed internal response time independent of channel count utilization.\u003c\/p\u003e\n\u003cp\u003eQ: Can inputs be paralleled for signal redundancy?\u003cbr\u003eA: Paralleling of inputs is supported electrically, but signal interpretation remains dependent on external wiring topology and PLC logic configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe BMXDDI1602H shall be installed on a grounded X80 rack backplane following standard DIN rail mechanical alignment procedures. Ensure that field wiring for 24 V DC inputs is segregated from high-voltage conductors to reduce electromagnetic coupling.\u003c\/p\u003e\n\u003cp\u003eShielded cable termination should be referenced to a single-point ground to prevent ground loop current through input common terminals. Maintain torque specifications for terminal blocks according to rack-level installation documentation.\u003c\/p\u003e\n\u003cp\u003eDo not exceed specified sensor supply voltage range during commissioning. Verify channel LED status indicators after power-up before enabling PLC scan execution.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44266277994584,"sku":"BMXDDI1602H","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/BMXDDI1602H-3.jpg?v=1782118715","url":"https:\/\/www.industriaxplc.com\/id\/products\/schneider-electric-bmxddi1602h-modicon-x80-discrete-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}