{"product_id":"schneider-electric-140ddo35310-modicon-quantum-discrete-output-module","title":"Schneider Electric 140DDO35310 Modicon Quantum Discrete Output Module","description":"\u003ch2\u003eSchneider Electric 140DDO35310 Modicon Quantum Discrete Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-density negative logic switching in the Modicon Quantum automation platform, the \u003cstrong\u003eSchneider Electric 140DDO35310\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e140DDO35310\u003c\/strong\u003e Discrete DC Output Module, provides direct physical execution of 32 sink-type output circuits operating at 24 V DC with deterministic response behavior.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode Segment\u003c\/th\u003e\n\u003cth\u003eDefinition\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e140\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum Series Prefix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDDO\u003c\/td\u003e\n\u003ctd\u003eDiscrete Digital Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e24 V DC Negative Logic (Sink)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e310\u003c\/td\u003e\n\u003ctd\u003e32-Point High Density Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Quantum Module Format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.0 W + (0.4 V x Total Load Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Current Requirement\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 330 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 (4 Groups of 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (Limits: 19.2–30 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Max Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V for 1 s decaying pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Drop\u003c\/td\u003e\n\u003ctd\u003e0.4 V @ 0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load Current\u003c\/td\u003e\n\u003ctd\u003e16 A per module \/ 4 A per group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5 A for 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1 ms (0-\u0026gt;1), \u0026lt;= 1 ms (1-\u0026gt;0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003e0.4 mA @ 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (Channel-Bus)\u003c\/td\u003e\n\u003ctd\u003e1780 Vrms DC for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (Group-Group)\u003c\/td\u003e\n\u003ctd\u003e500 Vrms DC for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eInternal 5 A fuse per group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicators\u003c\/td\u003e\n\u003ctd\u003e1 Green Active LED, 1 Red Fault LED, 32 Green Output Status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL 508, CSA C22.2 No 142, FM Class 1 Div 2, C-Tick, GOST, RINA, RMRS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity Licensing\u003c\/h3\u003e\n\u003cp\u003eThis module utilizes the Quantum backplane architecture to execute deterministic output updates synchronized with the PLC scan cycle. The 140DDO35310 requires allocation of 2 output words in the processor memory map. Channel state transitions are executed via direct backplane transactions without protocol translation latency. Firmware flash compatibility is bound to specific Quantum processor generations; mismatched firmware revisions may result in I\/O disable states during power-up diagnostics.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this module be hot-swapped while backplane power is applied?\u003c\/p\u003e\n\u003cp\u003eA: No. The 140DDO35310 must be inserted or removed only when the rack power supply is de-energized to prevent arcing on the backplane connectors and avoid transient overcurrent conditions on the internal fuses.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum permissible cable length for each output circuit?\u003c\/p\u003e\n\u003cp\u003eA: For 24 V DC negative logic outputs, total conductor length should be limited to 300 meters to minimize voltage drop and inductive ringing effects under high-speed switching loads.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support individual channel replacement without disturbing adjacent modules?\u003c\/p\u003e\n\u003cp\u003eA: No. Removal requires extraction from the Quantum rack; however, adjacent modules remain operational provided their own power budgets are maintained.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module on a standard Quantum backplane using the integrated locking mechanism. Ensure all DIN rail or chassis grounds are bonded to a single-point earth ground reference to suppress common-mode noise. Output wiring must use individually shielded twisted pair conductors with the shield terminated at the module end only. Fuse ratings must not exceed 3 A per point or 5 A per group. Verify absence of external field power before performing any terminal block connections.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44273323442264,"sku":"140DDO35310","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/140DDO35310-3.jpg?v=1782291907","url":"https:\/\/www.industriaxplc.com\/id\/products\/schneider-electric-140ddo35310-modicon-quantum-discrete-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}