{"product_id":"schneider-electric-140cps52400-power-supply-module","title":"Schneider Electric 140CPS52400 Power Supply Module","description":"\u003ch2\u003eSchneider Electric 140CPS52400 Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchneider Electric 140CPS52400\u003c\/strong\u003e serves as the primary \u003cstrong\u003e140CPS52400 Power Supply Module\u003c\/strong\u003e utilized to execute redundant DC power conversion and backplane distribution across Modicon Quantum automation platforms. The module converts 100...150 V DC input into regulated 5.1 V DC backplane output with dual-redundant 8 A load sharing capability.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eNo validated suffix segmentation or functional sub-code structure is defined for 140CPS52400 within the provided technical dataset. The designation is treated as a single-order hardware identifier mapped directly to its redundant power supply function.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric 140CPS52400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.65 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 cm x 2.5 cm x 2.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e6 + (1.5 x Iout)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100...150 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e5.1 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e8 A (redundant configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e28 A at 125 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eInternal overvoltage and overload protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Power Distribution and Redundancy Behavior\u003c\/h3\u003e\n\u003cp\u003eWithin Modicon Quantum architecture, the 140CPS52400 implements regulated backplane power injection with redundant current-sharing logic between paired supply modules. Backplane voltage stability is maintained through internal regulation stages that decouple transient load variations from the shared bus structure. Firmware-level monitoring supervises redundancy status and inhibits cross-coupled instability during asymmetric loading conditions, ensuring deterministic power availability for downstream I\/O racks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 140CPS52400 be hot-swapped under load conditions?\u003cbr\u003eA: The module supports rack-level redundancy; however, hot-swap behavior is constrained by system configuration and backplane current state. Load transfer is managed through redundant pairing logic.\u003c\/p\u003e\n\u003cp\u003eQ: What happens if one redundant power module fails?\u003cbr\u003eA: The remaining module assumes full load output up to rated 8 A capacity while internal diagnostics trigger a fault indication via front-panel LED signaling.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module require external overcurrent protection?\u003cbr\u003eA: A recommended 2 A slow-blow fuse is specified on the input side to protect against upstream DC supply faults and inrush conditions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the 140CPS52400 is inserted into a compatible Modicon Quantum rack slot with verified backplane alignment. Maintain correct polarity for 125 V DC input wiring and verify grounding continuity across the chassis frame. Redundant modules must be installed in designated paired positions to enable load-sharing operation. Shielded DC conductors are recommended to minimize electromagnetic coupling on high inrush events.\u003c\/p\u003e\n\u003cp\u003eAvoid energizing the rack until both redundant modules are fully seated and mechanical locking is engaged.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44278436855896,"sku":"140CPS52400","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/140CPS52400-3.jpg?v=1782440197","url":"https:\/\/www.industriaxplc.com\/id\/products\/schneider-electric-140cps52400-power-supply-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}