{"product_id":"schneider-800-series-dap-208-modicon-digital-output-modules","title":"Schneider Electric DAP 208 Modicon 800 Series Digital Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\u003cp\u003eThe Schneider Electric DAP 208 is a specialized relay output module designed for the Modicon 800 Series I\/O architecture. This unit provides eight independent electromechanical output channels, functioning as an interposing interface between low-voltage controller logic and higher-voltage field load circuits. By utilizing mechanical relay contacts, the module ensures robust galvanic isolation, protecting sensitive backplane communication buses from field-side inductive surges, electrical noise, and potential short-circuit events common in demanding industrial environments such as power generation and chemical processing.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEight independent, normally open (NO) electromechanical relay outputs.\u003c\/li\u003e\n\u003cli\u003eSingle-slot modular design for efficient space utilization within 800 Series backplane frames.\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between the backplane bus and field-side load circuits to enhance system integrity.\u003c\/li\u003e\n\u003cli\u003eIntegrated snubber networks on each channel to suppress inductive counter-electromotive force during switching.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators providing real-time status mapping for each individual output channel.\u003c\/li\u003e\n\u003cli\u003eRemovable screw terminal block assembly for simplified field wiring and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is engineered for high-capacity switching requirements in heavy industry, including petroleum refineries, thermal power plants, and mineral processing facilities. It is ideal for driving external contactors, solenoid valves, and indicator lamps where electrical separation between the PLC logic and the field device is required for safety and noise immunity.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDAP 208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 (Normally Open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 to 240 VAC \/ 24 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating (Per Point)\u003c\/td\u003e\n\u003ctd\u003e2.0 A (Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Module Current\u003c\/td\u003e\n\u003ctd\u003e12.0 A (Cumulative Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (Contact-to-Backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e320 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the controller backplane is powered down before inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the backplane slot and secured with provided locking mechanisms.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for field connections to minimize EMI\/RFI interference in high-noise environments.\u003c\/li\u003e\n\u003cli\u003eMaintain proper clearance around the module to ensure adequate airflow for cooling.\u003c\/li\u003e\n\u003cli\u003eAdhere to the cumulative current limit of 12.0 A to prevent thermal degradation of the module circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the DAP 208 module?\u003c\/strong\u003e\u003cbr\u003eThe DAP 208 acts as a digital output interface that uses mechanical relays to switch field loads, providing electrical isolation between the Modicon 800 Series controller and external devices.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAre the output channels individually isolated?\u003c\/strong\u003e\u003cbr\u003eYes, the module features internal dielectric barriers to provide galvanic separation between the outputs and the backplane data bus, as well as between adjacent channels.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat type of field devices can this module drive?\u003c\/strong\u003e\u003cbr\u003eIt is designed to drive standard industrial loads such as solenoids, relays, contactors, and signaling lamps within the specified voltage and current ratings.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":44731394850904,"sku":"DAP 208","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_821cbe86-bbc3-4707-ad62-9b46b7fea98b.jpg?v=1788671424","url":"https:\/\/www.industriaxplc.com\/id\/products\/schneider-800-series-dap-208-modicon-digital-output-modules","provider":"IndustriaX Limited","version":"1.0","type":"link"}