{"product_id":"mu-paoy22-honeywell-analog-output-16-point-processor-fta","title":"MU-PAOY22 Honeywell Analog Output 16-Point Processor\/FTA","description":"\u003ch2\u003eHoneywell MU-PAOY22 Analog Output 16-Point Processor\/FTA\u003c\/h2\u003e\n\u003cp\u003eConfigured for 4-20 mA analog signal execution in Honeywell process control I\/O environments, the \u003cstrong\u003eHoneywell MU-PAOY22\u003c\/strong\u003e (\u003cstrong\u003eMU-PAOY22\u003c\/strong\u003e Analog Output 16-Point Processor\/FTA) provides direct physical and electrical output conversion from digital input codes to field current signals.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMU-PAOY22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output 16-Point Processor\/FTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFTA Models\u003c\/td\u003e\n\u003ctd\u003eMU-TAOY22, MU-TAOY23, MU-TAOY52, MU-TAOY53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ripple\u003c\/td\u003e\n\u003ctd\u003e100 mV peak-to-peak at power line frequency across 250 ohm load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Temperature Stability\u003c\/td\u003e\n\u003ctd\u003e+\/-0.02% Full Scale\/deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Readback Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Effect\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% full scale at 50% RH +\/-40% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Linearity\u003c\/td\u003e\n\u003ctd\u003e+\/-0.05% nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e+\/-0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrated Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.35% at 25 deg C including linearity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirectly Settable Output Current Range\u003c\/td\u003e\n\u003ctd\u003e0 mA, 2.9 mA to 21.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Maximum Current Output\u003c\/td\u003e\n\u003ctd\u003e24 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resistive Load\u003c\/td\u003e\n\u003ctd\u003e750 ohm at 24 V supply and 20 V output compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Compliant Voltage\u003c\/td\u003e\n\u003ctd\u003e15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Settling Time\u003c\/td\u003e\n\u003ctd\u003e4 ms from digital input code to 98% final output value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Withstand Capability\u003c\/td\u003e\n\u003ctd\u003eANSI\/IEEE C37.90.1-1978\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell 4-20 mA Process Control Output Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe MU-PAOY22 provides sixteen independent analog output channels with a 4-20 mA current interface. Therefore, the module converts internal digital control values into proportional field current signals for process actuators, control valves, and analog input devices.\u003c\/p\u003e\n\u003cp\u003eThe output stage supports direct current adjustment from 0 mA and 2.9 mA to 21.1 mA. In addition, the module maintains calibrated accuracy within +\/-0.35% at 25 deg C while controlling current linearity within +\/-0.05% nominal.\u003c\/p\u003e\n\u003cp\u003eThe design supports process control requirements involving channel-to-channel signal management and stable analog transmission. Furthermore, the output circuit provides surge withstand capability according to ANSI\/IEEE C37.90.1-1978 requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of field signal does the Honeywell MU-PAOY22 generate?\u003cbr\u003eA: The MU-PAOY22 generates 4-20 mA analog current output signals through 16 independent output channels.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum resistive load supported by each output channel?\u003cbr\u003eA: Each output channel supports a maximum resistive load of 750 ohm when the supply condition is 24 V with 20 V output compliance.\u003c\/p\u003e\n\u003cp\u003eQ: How fast does the output signal reach the commanded value?\u003cbr\u003eA: The module reaches 98% of the final output value within 4 ms after receiving the digital input code.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the MU-PAOY22 according to Honeywell system hardware installation procedures and approved cabinet wiring practices.\u003c\/p\u003e\n\u003cp\u003eUse shielded cables for analog current loops when the installation environment contains electrical noise sources. Connect cable shields according to the control system grounding design to reduce signal interference.\u003c\/p\u003e\n\u003cp\u003eSeparate analog output wiring from high-voltage power conductors and switching circuits. Maintain proper terminal identification during field wiring to prevent incorrect current loop connections.\u003c\/p\u003e\n\u003cp\u003eVerify the output loop resistance before commissioning. Confirm that connected field devices remain within the module output compliance voltage and current capability limits.\u003c\/p\u003e\n\u003cp\u003eCheck channel operation by applying controlled digital output commands and measuring the corresponding 4-20 mA field current response.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44402748260440,"sku":"MU-PAOY22","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/MU-PAOY22-2.jpg?v=1784530761","url":"https:\/\/www.industriaxplc.com\/id\/products\/mu-paoy22-honeywell-analog-output-16-point-processor-fta","provider":"IndustriaX Limited","version":"1.0","type":"link"}