{"product_id":"mu-kfta08-field-termination-assembly-honeywell","title":"MU-KFTA08 Field Termination Assembly | Honeywell","description":"\u003ch2\u003eHoneywell MU-KFTA08 Field Termination Assembly\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MU-KFTA08 (51201420-008)\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMU-KFTA08\u003c\/strong\u003e Field Termination Assembly, operates as a dedicated hardware interface component for field signal termination and electrical distribution within Honeywell TDC 3000 and Experion PKS HPM systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMU-KFTA08\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive termination assembly; no independent power consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51201420-008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Type\u003c\/td\u003e\n\u003ctd\u003eField Termination Assembly (FTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 3000 \/ Experion PKS \/ HPM systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Interface\u003c\/td\u003e\n\u003ctd\u003eField wiring termination and I\/O signal routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eStandard FTA mounting panel installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Method\u003c\/td\u003e\n\u003ctd\u003eScrew terminal field connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eIndustrial conformal coating protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003eConfiguration dependent; verify installed FTA drawing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Signal Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe MU-KFTA08 provides the physical termination point between field wiring and Honeywell process control I\/O modules. It manages field-side signal routing through dedicated terminal connections and connects to control processors through Honeywell FTA cable assemblies.\u003c\/p\u003e\n\u003cp\u003eIn addition, the assembly supports process instrumentation interfaces commonly associated with Honeywell DCS architectures, including 4-20 mA HART loop applications, FOUNDATION Fieldbus or Profibus PA field connectivity when used with compatible I\/O configurations, and channel-to-channel isolation requirements defined by the connected I\/O hardware.\u003c\/p\u003e\n\u003cp\u003eThe FTA design separates field wiring activities from controller cabinet wiring. Therefore, maintenance personnel can inspect, replace, or modify field connections without directly disturbing processor-side modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the MU-KFTA08 contain active signal processing electronics?\u003cbr\u003eA: The MU-KFTA08 functions as a Field Termination Assembly and primarily provides field wiring termination and signal routing. Active signal processing depends on the connected Honeywell I\/O module.\u003c\/p\u003e\n\u003cp\u003eQ: Can the MU-KFTA08 be installed without verifying terminal assignments?\u003cbr\u003eA: No. Field wiring terminals must match the approved Honeywell TDC 3000 or Experion PKS installation drawings because terminal allocation depends on the connected I\/O configuration.\u003c\/p\u003e\n\u003cp\u003eQ: Does the MU-KFTA08 require external power wiring?\u003cbr\u003eA: The FTA itself does not require independent power input. Power requirements are determined by the associated I\/O module and field device loop design.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the MU-KFTA08 on the specified Honeywell FTA mounting hardware according to the system cabinet layout documentation.\u003c\/li\u003e\n\u003cli\u003eVerify all field cable identification before termination to prevent channel assignment errors.\u003c\/li\u003e\n\u003cli\u003eMaintain separation between low-level analog signal wiring and high-voltage power conductors to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the approved grounding method defined by the control system installation standard.\u003c\/li\u003e\n\u003cli\u003eConfirm terminal polarity and signal type before connecting transmitters, switches, or actuator feedback circuits.\u003c\/li\u003e\n\u003cli\u003eInspect screw terminal torque and conductor seating during commissioning activities.\u003c\/li\u003e\n\u003cli\u003eUse the approved Honeywell FTA cable assembly between the termination unit and the corresponding I\/O processor interface.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44402877399128,"sku":"MU-KFTA08 51201420-008","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/MU-KFTA0851201420-008.jpg?v=1784531883","url":"https:\/\/www.industriaxplc.com\/id\/products\/mu-kfta08-field-termination-assembly-honeywell","provider":"IndustriaX Limited","version":"1.0","type":"link"}