{"product_id":"mu-gaox12-51304638-325-honeywell-analog-output-module","title":"MU-GAOX12 51304638-325 | Honeywell | Analog Output Module","description":"\u003ch2\u003eHoneywell MU-GAOX12 Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MU-GAOX12 51304638-325\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMU-GAOX12\u003c\/strong\u003e Analog Output Module, operates as a dedicated hardware component for converting DCS control commands into isolated analog output signals within Honeywell Experion PKS and TDC 3000 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMU-GAOX12 51304638-325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003ePlug-in I\/O module format, dimensions not specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS \/ TDC 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Level Analog Output (HLAO), galvanically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e12 or 16 channels depending on system integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 1-5 VDC, or 0-10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Conversion\u003c\/td\u003e\n\u003ctd\u003e12-bit to 16-bit DAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1% full scale at standard operating conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Resistance\u003c\/td\u003e\n\u003ctd\u003e750 ohm at 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Method\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\u003ctd\u003eSurge protection, open loop detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eHoneywell I\/O chassis plug-in module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation and Process Signal Interface\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell MU-GAOX12 51304638-325 provides isolated analog signal generation between the control processor and field-level actuators. The module converts internal digital commands into continuous current or voltage outputs for control valves, actuators, and variable speed drive interfaces.\u003c\/p\u003e\n\u003cp\u003eThe module supports standard process control output ranges, including 4-20 mA current loops and voltage output configurations. In addition, channel-to-channel isolation reduces ground loop influence and separates field wiring disturbances from internal control electronics.\u003c\/p\u003e\n\u003cp\u003eFor Honeywell DCS applications, the analog output architecture supports direct field control execution. Furthermore, the module can integrate with process instrumentation networks using standard Honeywell I\/O subsystem configurations.\u003c\/p\u003e\n\u003ch3\u003e4-20 mA HART Loop and DCS Output Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe MU-GAOX12 follows Honeywell process control I\/O design principles with isolated analog signal handling. The module supports current loop applications commonly used with proportional valves, actuators, and field controllers.\u003c\/p\u003e\n\u003cp\u003eChannel isolation protects individual output paths from wiring faults and transient disturbances. Additionally, open loop detection allows the control system to identify broken field connections and generate diagnostic information.\u003c\/p\u003e\n\u003cp\u003eThe module operates as an output-side interface only and does not perform field signal measurement. Therefore, input conversion functions, cold junction compensation (CJC), and field transmitter processing are handled by separate Honeywell input modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of signals does the Honeywell MU-GAOX12 51304638-325 output?\u003cbr\u003eA: The module provides analog output signals including 4-20 mA current loops and configurable voltage outputs such as 1-5 VDC or 0-10 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: Does the MU-GAOX12 51304638-325 provide channel isolation?\u003cbr\u003eA: Yes. The module provides galvanic channel-to-channel isolation to reduce ground loop effects and protect internal control electronics.\u003c\/p\u003e\n\u003cp\u003eQ: Can the MU-GAOX12 51304638-325 operate as an analog input module?\u003cbr\u003eA: No. The MU-GAOX12 51304638-325 is an analog output module designed for converting DCS commands into field control signals.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the MU-GAOX12 51304638-325 into the specified Honeywell I\/O chassis or compatible baseplate according to system hardware documentation.\u003c\/p\u003e\n\u003cp\u003eVerify module seating before applying system power. Connect field output wiring according to the approved terminal assignment and maintain proper separation between analog signal cables and high-voltage wiring.\u003c\/p\u003e\n\u003cp\u003eUse shielded cables for analog output connections when required by the installation environment. Connect cable shields according to site grounding practices to minimize electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, verify output loop continuity, field device response, and controller channel configuration. Confirm that the installed hardware revision matches the applicable Honeywell system configuration documentation.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44402895585368,"sku":"MU-GAOX12 51304638-325","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/MU-GAOX1251304638-325-3.jpg?v=1784532426","url":"https:\/\/www.industriaxplc.com\/id\/products\/mu-gaox12-51304638-325-honeywell-analog-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}