{"product_id":"is400uclih1a-ge-industrial-controller-module","title":"IS400UCLIH1A GE Industrial Controller Module","description":"\u003ch2\u003eGE IS400UCLIH1A Industrial Controller Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS400UCLIH1A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS400UCLI\u003c\/strong\u003e Industrial Controller Module, operates as a dedicated hardware component for real-time control execution and data communication within GE Speedtronic Mark V \/ Mark VIe control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS400UCLIH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e72 x 36 x 85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC supply, 5 A current input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eHigh-speed industrial CPU for real-time control processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eVolatile and non-volatile memory with Flash and RAM support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eEthernet, serial, fieldbus, and GE proprietary protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Support\u003c\/td\u003e\n\u003ctd\u003eModular I\/O expansion interface for control system integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRack installation, DIN rail, or panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP and Control Bus Execution Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe IS400UCLIH1A is configured as a control processor module within GE Speedtronic Mark V \/ Mark VIe architectures. The module executes application logic, manages real-time I\/O data exchange, and communicates with distributed control components through supported Ethernet, serial, fieldbus, and proprietary communication channels.\u003c\/p\u003e\n\u003cp\u003eThe controller architecture supports modular I\/O density scaling through connected input and output assemblies. Firmware flash compatibility allows application software updates and controller configuration management within the supported GE control environment.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power input is required for the IS400UCLIH1A controller module?\u003cbr\u003eA: The module operates from a 24 VDC power source with a specified current requirement of 5 A.\u003c\/p\u003e\n\u003cp\u003eQ: Does the IS400UCLIH1A support replacement without system shutdown?\u003cbr\u003eA: The module design supports hot-swappable replacement procedures when applied within a compatible GE rack configuration and according to system installation requirements.\u003c\/p\u003e\n\u003cp\u003eQ: Which communication interfaces are available on this controller module?\u003cbr\u003eA: The module supports Ethernet, serial communication, fieldbus interfaces, and GE proprietary communication protocols.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS400UCLIH1A in the designated GE Speedtronic Mark V \/ Mark VIe rack or approved mounting assembly. Verify mechanical seating, connector alignment, and power isolation before module insertion or removal.\u003c\/p\u003e\n\u003cp\u003eUse shielded communication cables where required by the control system design. Connect cable shields according to site grounding practices to reduce electromagnetic interference. Separate communication wiring from high-voltage power conductors and maintain appropriate cable routing practices.\u003c\/p\u003e\n\u003cp\u003eConfirm firmware compatibility, controller configuration parameters, and I\/O addressing before commissioning. Ensure ventilation paths remain unobstructed and that environmental conditions remain within the specified operating range.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44391136362584,"sku":"IS400UCLIH1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS400UCLH1A.jpg?v=1784277030","url":"https:\/\/www.industriaxplc.com\/id\/products\/is400uclih1a-ge-industrial-controller-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}