{"product_id":"is200trtdh1c-ge-rtd-input-board","title":"IS200TRTDH1C GE RTD Input Board","description":"\u003ch2\u003eGE IS200TRTDH1C RTD Input Terminal Board\u003c\/h2\u003e\n\u003cp\u003eConfigured for RTD signal acquisition in the GE Mark VI\/Mark VIe Speedtronic turbine control system, the \u003cstrong\u003eGE IS200TRTDH1C\u003c\/strong\u003e (\u003cstrong\u003eIS200TRTDH1C\u003c\/strong\u003e RTD Input Terminal Board) provides direct physical signal termination and conditioning for temperature sensor inputs. The board interfaces RTD devices with turbine control hardware through conditioned analog channels for temperature measurement functions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TRTDH1C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e22 cm x 17 cm x 4.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC input, 150-200 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRTD Input Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels supported (application configuration may vary)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Sensor Types\u003c\/td\u003e\n\u003ctd\u003ePT100, copper 10 ohm, nickel 120 ohm RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Wiring\u003c\/td\u003e\n\u003ctd\u003e2-wire and 3-wire RTD connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Measurement Range\u003c\/td\u003e\n\u003ctd\u003e-200 to +850 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation Current\u003c\/td\u003e\n\u003ctd\u003e1 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.5 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10 Mohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHost Interface\u003c\/td\u003e\n\u003ctd\u003e50-pin ribbon connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Connector\u003c\/td\u003e\n\u003ctd\u003e6-pin terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Construction\u003c\/td\u003e\n\u003ctd\u003e4-layer PCB with guarded analog traces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI \/ Mark VIe Speedtronic control systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE RTD Signal Conditioning and Mark VIe Interface\u003c\/h3\u003e\n\u003cp\u003eThe IS200TRTDH1C performs RTD input termination, excitation, and analog signal conditioning before data transfer to the Mark VIe controller architecture. The guarded analog trace layout and filtering components are configured to reduce electrical noise effects on low-level temperature measurement signals.\u003c\/p\u003e\n\u003cp\u003eThe board supports Mark VIe control architectures including simplex, duplex, and TMR configurations when installed within compatible system hardware. RTD channel processing maintains sensor scaling and measurement conversion for turbine temperature monitoring applications.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What RTD sensor connections are supported by the IS200TRTDH1C?\u003cbr\u003eA: The board supports 2-wire and 3-wire RTD connections, including PT100 and other resistance-based temperature sensors.\u003c\/p\u003e\n\u003cp\u003eQ: What is the power input requirement for this terminal board?\u003cbr\u003eA: The board operates from a 24 VDC supply with a typical current consumption range of 150-200 mA.\u003c\/p\u003e\n\u003cp\u003eQ: Does the IS200TRTDH1C provide direct temperature measurement output?\u003cbr\u003eA: The board conditions RTD analog signals and transfers processed input data through the Mark VIe control system interface.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS200TRTDH1C in the designated GE Mark VI\/Mark VIe turbine control rack location using the approved mounting hardware and connector interfaces.\u003c\/p\u003e\n\u003cp\u003eRTD signal wiring should be routed separately from high-current power conductors and switching circuits to reduce electromagnetic interference. Shielded instrumentation cables should be used where required, with cable shields terminated according to the control system grounding design.\u003c\/p\u003e\n\u003cp\u003eVerify RTD polarity, channel assignment, connector seating, and supply voltage before system startup. Avoid modifying PCB components or analog signal paths during installation or maintenance activities.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44403068698712,"sku":"IS200TRTDH1C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200TRTDH1DCB.jpg?v=1784538162","url":"https:\/\/www.industriaxplc.com\/id\/products\/is200trtdh1c-ge-rtd-input-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}