{"product_id":"ics-triplex-tc-505-02-4m5-smartslot-companion-slot-i-o-cable-assembly","title":"ICS Triplex TC-505-02-4M5 SmartSlot \/ Companion Slot I\/O Cable Assembly","description":"\u003ch2\u003eICS Triplex TC-505-02-4M5 SmartSlot \/ Companion Slot I\/O Cable Assembly\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eICS Triplex TC-505-02-4M5\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTC-505\u003c\/strong\u003e SmartSlot \/ Companion Slot I\/O Cable Assembly, provides direct physical signal routing between 40-channel safety I\/O modules and associated field termination or power distribution assemblies within the Trusted TMR system.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-505-02-4M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eTC-505\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICS Triplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSmartSlot \/ Companion Slot I\/O Cable Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eTrusted TMR Safety System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eInternal cabinet I\/O signal and power distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e40 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Connector\u003c\/td\u003e\n\u003ctd\u003e96-way Type C connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Connector\u003c\/td\u003e\n\u003ctd\u003e96-way Type R connector configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e4.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC \/ up to 60 VDC safety loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable assembly; no separate consumption specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTMR Signal Path and Electrical Isolation\u003c\/h3\u003e\n\u003cp\u003eThe TC-505-02-4M5 provides prefabricated point-to-point connections for Trusted TMR I\/O hardware. The 96-way chassis connector mates with the specified cabinet-side interface, while the remote connector configuration routes signals toward the applicable FTA or power distribution assembly.\u003c\/p\u003e\n\u003cp\u003eBecause the cable assembly carries safety-system I\/O connections, installation should preserve the physical segregation used by the TMR architecture. Furthermore, the cable should not introduce unintended connections between redundant signal paths.\u003c\/p\u003e\n\u003cp\u003eThe supplied data identifies the assembly with 40-channel I\/O applications and 24 VDC to 60 VDC safety-loop operation. However, the available information does not specify a separate galvanic-isolation rating for the cable itself; therefore, isolation should be attributed to the associated Trusted I\/O hardware rather than the cable assembly.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the cable length of the TC-505-02-4M5?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied specification identifies a cable length of 4.5 m.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which connectors does the TC-505-02-4M5 use?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied data specifies a 96-way Type C connector at the chassis end and a 96-way Type R configuration at the field or remote end.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the cable assembly consume electrical power?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No separate power consumption is specified because the TC-505-02-4M5 functions as a passive interconnection assembly.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the TC-505-02-4M5 part number before installation and confirm connector compatibility with the associated Trusted I\/O hardware.\u003c\/li\u003e\n\u003cli\u003eRoute the cable without excessive bending, tensile loading, or mechanical compression.\u003c\/li\u003e\n\u003cli\u003eMaintain the cabinet segregation between redundant TMR signal paths and unrelated power circuits.\u003c\/li\u003e\n\u003cli\u003eSecure the cable so that connector bodies do not carry mechanical loads.\u003c\/li\u003e\n\u003cli\u003eFully seat and secure each connector before energizing the associated I\/O assembly.\u003c\/li\u003e\n\u003cli\u003eKeep signal wiring separated from high-current switching conductors where the cabinet design permits.\u003c\/li\u003e\n\u003cli\u003eDo not modify, splice, or reterminate the prefabricated cable unless the system documentation explicitly permits the modification.\u003c\/li\u003e\n\u003cli\u003eFollow the grounding and shielding requirements specified for the associated Trusted I\/O and FTA hardware.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":44547569287256,"sku":"TC-505-02-4M5","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TC-505-02-4M5-3_1200x1200_8ea185ee-d072-4786-ab8c-6da854c8e908.jpg?v=1786350777","url":"https:\/\/www.industriaxplc.com\/id\/products\/ics-triplex-tc-505-02-4m5-smartslot-companion-slot-i-o-cable-assembly","provider":"IndustriaX Limited","version":"1.0","type":"link"}